INSTALLATION MANUAL
TABLE “A” - PARAMETERS MENU - (
PARA
)
Parameter
min.
max.
Default Personal
Definition
Description
TCA
0
120
120
Automatic
closing time [s]
Waiting time before automatic closing.
TRF.LGHT.
CLR.T
1
180
40
Time-to-clear
traffic light zone
[s]
Time-to-clear for the zone run through by traffic controlled by the traffic light.
t. start
30
250
150
Inrush time
Inrush time at each motor startup, during which obstacle detection is not active. Given in hun-
dredths of a second (150=1.5 s).
output time
1
240
10
Activation time of
the timed output
[s]
Activation length of timed radio channel output in seconds
OP.DIST.
SLOUD
1
50
10
Slow-down
distance during
opening [%]
Slow-down distance for motor(s) during opening, given as a percentage of total
travel.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
CL.DIST.
SLOUD
5
50
10
Slow-down
distance during
closing [%]
Slow-down distance for motor(s) during closing, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
DIST.DECEL
0
50
15
Deceleration
distance [%]
Deceleration distance (switch from running speed to slow-down speed) for motor(s) both
during opening and during closing, given as a percentage of total travel.
WARNING: Once the
parameter has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
PARTIAL
OPENING
10
99
40
Partial opening
[%]
Partial opening distance as a percentage of total opening following activation of PED pedestrian
command.
SWC pressu-
re force
1
99
20
Leaf pressure for-
ce on the closure
limit-switch [%]
The force exerted by the leaf during the pressure on the closure limit-switch.
OP.FORCE
1
99
50
Leaf force during
opening [%]
Force exerted by leaf during opening. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
CLS.FORCE
1
99
50
Leaf force during
closing [%]
Force exerted by leaf during closing. This is the percentage of force delivered, beyond
the force stored during the autoset cycle (and subsequently updated), before an
obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
OP SPEED
15
99
99
Opening speed
[%}
Percentage of maximum speed that can be reached by motor(s) during opening.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
CL SPEED
15
99
70
Closing speed
[%]
Percentage of maximum speed that can be reached by motor(s) during closing.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
SLOW SPEED
15
50
20
Slow-down
speed [%]
Opening and closing speed of motor(s) during slow-down stage, given as a percentage of
maximum running speed.
WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: When the display reads
“”SET””, obstacle detection is not active.
Maintenance
0
250
0
Programming
number of
operations for
maintenance
threshold
[in hundreds]
Allows you to set a number of operations after which the need for maintenance will be repor-
ted on the AUX output configured as Maintenance or Flashing Light and Maintenance .
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.