USER’S MANUAL

ENGLISH

Thank you for buying this product, our company is sure that you will be more 
than satisfied with the product’s performance. The product is supplied with 
a “

Warnings

” leaflet and an “

Instruction booklet

”. These should both be 

read carefully as they provide important information about safety, installa-
tion, operation and maintenance. This product complies with the recognised 
technical standards and safety regulations. 

1) GENERAL OUTLINE

The 

DEIMOS  BT  UL

  actuator  offers  ample  installation  versatility  thanks 

to its compactness, the extremely low position of its pinion as well as the 
height and depth adjustments available. The adjustable electronic torque 
limiter ensures antisquash safety. The emergency manual manoeuvre can be 
activated very easily by means of a knob. The end-of-run stop is controlled 
by electromechanical limit microswitches. The control unit is incorporated. 
Before each manoeuvre, the control unit performs a check of the operation 
relays and safety devices (photocells, rubber skirt, etc.).
The incorporated control panel checks the drive relays and safety devices 
(photocells and safety edge) before carrying out any manoeuvre. 
The following optional accessories are available:

- SBBAT mod. Buffer battery kit

It can be incorporated into the actuator, and allows the automation system to 
operate even when the mains power supply is disconnected for a short time.

- MSC mod. Release knob 

(fig.2)

Fixed release knob with personalised key.

2) SAFETY

If correctly installed and used, this automation device satisfies the required 
safety level standards. However, it is advisable to observe some practical 
rules in order to avoid accidental problems.  
Before using the automation device, carefully read the operation instructions 
and keep them for future reference.
•  Keep children, persons and things outside the automation working area, 

particularly during operation. 

•  Keep  radio  control  or  other  control  devices  out  of  children’s  reach,  in 

order to avoid any unintentional automation activation. 

•  Do not intentionally oppose the leaf movement. 
•  Do not attempt to open the gate by hand, if the actuator has not been 

released by means of the appropriate release knob.  

•  Do not modify the automation components. 
•  In case of malfunction, disconnect the power supply, activate the emer-

gency release to gain access to the actuator and request the assistance 
of a qualified technician (installer). 

•  Before  proceeding  to  any  external  cleaning  operation,  disconnect  the 

mains powers supply and at least one of the battery pole, if fitted. 

•  Keep the photocell optical components and luminous signal indication 

devices clean. Check that the safety devices (photocells) are not obscured 
by branches or shrubs.

•  For any direct assistance to the automation system, request the assistance 

of a qualified technician (installer). 

•  Have qualified personnel check the automation system once a year.
• 

Entrance is reserved for vehicles, provide a separate entrance for 
pedestrians.

3) MANUAL RELEASE

The  manual  or  emergency  release  is  to  be  activated  when  a  gate  must 
be opened by hand, and in all cases where the automation system fails to 
operate  or  operates  incorrectly. To  carry  out  the  emergency  manoeuvre, 
proceed as follows: 
•  Insert the standard key into its appropriate seat (fig. 1) and rotate it an-

ticlockwise (90°), then rotate the release knob clockwise along its entire 
stroke. This way the pinion is made to idle, and therefore allows the gate 
to be opened by hand.

  Warning: Do not push the gate leaf hard, but rather help it along its 

entire stroke. 

•  To reset motor-driven control, rotate the knob anticlockwise along its entire 

stroke, and then rotate the standard key clockwise until it is held tight. Keep 
the key in a safe place which is known to all the people concerned. 

In  the  case  where  the  release  knob  is  supplied  with  a  personalised  key 
(fig.2), proceed as follows:
•  Insert the personalised key into the lock, rotate the key anticlockwise by 

90°.

•  Hold the release knob and rotate it clockwise (fig. 2) until it stops. This 

way the pinion is made to idle, and therefore allows the gate to be opened 
by hand.

•  Push the gate leaf by hand, helping it along its entire stroke. 
  The key cannot be taken out of the lock until the knob is brought back to 

its initial position (motor-driven activation).

•  To reset motor-driven control, rotate the knob anticlockwise along its entire 

stroke, move the key back to its locking position; then take the key out 
and keep it in a safe place which is known to all the people concerned. 

4) MAINTENANCE AND DEMOLITION

The  maintenance  of  the  system  should  only  be  carried  out  by  qualified 
personnel regularly

.

 The materials making up the set and its packing must 

be disposed of according to the regulations in force.

WARNINGS

The installation of the two supplied placards is required in the area of the 
gate and in a location where they are clearly visible.

 (Fig.12).

Correct controller operation is only ensured when the data contained in 
the present manual are observed. The company is not to be held respon-
sible for any damage resulting from failure to observe the installation 
standards

 

and the instructions contained in the present manual.

The descriptions and illustrations contained in the present manual are 
not binding. The Company reserves the right to make any alterations 
deemed appropriate for the technical, manufacturing and commercial 
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the 
present publication.

Fig. 1

OPEN

CLOSE

Fig. 2

1

2

OPEN

CLO

SE

1

2

OPEN

CLOSE

MSC

DEIMOS BT UL Ver. 07 - 

3

D811419_07

Summary of Contents for DEIMOS BT KIT UL

Page 1: ...Tel int 39 0445 696533 Fax 0445 696522 Internet www bft it E mail sales bft it ATTUATORE IN BASSA TENSIONE PER CANCELLI SCORREVOLI A CREMAGLIERA LOW VOLTAGE ACTUATOR FOR RACK SLIDING GATES DEIMOS BT U...

Page 2: ...ll automazione avvalersidipersonalequalificato installatore Annualmente far controllare l automazione da personale qualificato L entrata riservata ai veicoli Prevedere un entrata separata per i pedoni...

Page 3: ...y branches or shrubs Foranydirectassistancetotheautomationsystem requesttheassistance of a qualified technician installer Have qualified personnel check the automation system once a year Entrance is r...

Page 4: ...ono disponibili i seguenti accessori opzionali Kit batteria tampone mod SBBAT Incorporabile nell attuatore consente il funzionamento dell automazione anche se manca per un breve periodo l alimentazion...

Page 5: ...del l uso del cancello e non risolve problemi dovuti a difetti e deficienze di installazione o di mancata manutenzione del cancello stesso Togliere il prodotto dall imballo e verificarne l integrit S...

Page 6: ...ci CEI 64 8 IEC364 armonizzazione HD384 ed altre norme nazionali ATTENZIONE Per il collegamento alla rete utilizzare cavo multipolare di sezione minima 3x16AWG e del tipo previsto dalle normative vige...

Page 7: ...i rallentamento in chiusura e in apertura si ottiene cro nometrando la durata di una manovra ed impostando un valore minore in questo parametro Se ad esempio la durata di una manovra di 15 secondi imp...

Page 8: ...UTOset Consente di effettuare il settaggio automatico della Coppia motori ATTENZIONE L operazione di autosettaggio va effettuata da finecorsa di chiusura Se si prova ad effettuare l Autoset in una pos...

Page 9: ...la manopola non viene riportata nella posizione iniziale azionamento motorizzato Per ripristinare il comando motorizzato ruotare la manopola in senso antiorario per tutta la sua corsa e togliere la ch...

Page 10: ...M P OK OK PM P B M ON OFF ML P OK OK AMB 11M ON OFF M P OK OK OK P R T LMPK OK OK P R T LMPK AF OK OK P T P OK OK 8MLC P OK OK P A P OK OK P A AF P OK 1R P ON OFF M P OK OK MM ON OFF M P OK Fig A OK P...

Page 11: ...M L QAMQRM PGJ QAG R QRM BCQGBCP RM 0 CEEG MENU RADIO AGGIUNGI Consente di aggiungere un tasto di un radiocomando nella memoria della ricevente dopo la memorizzazione restituisce numero del trasmettit...

Page 12: ...he drive relays and safety devices photocells and safety edge before carrying out any manoeuvre M Motor R Reduction gear with worm screw and wheel F Electromechanical limit switch unit P Pinion S Rele...

Page 13: ...laced in order to fix the reduction gear unit fig 3 If the sliding track is already there digging must be partly carried out in the track foundation casting This way should the track foundation castin...

Page 14: ...able having a minimum cross section of 3x16 AWG and complying with the current standards For example if the cable is not protected it must be at least equal to H07 RN F whereas if it is protected it m...

Page 15: ...otor torque between 1 and 99 Slow down closing motor torque cls t slow 50 Advanced parameters address 9 Set the numerical value of the motor torque between 1 and 99 Fast Opening Time op speed time 15...

Page 16: ...rque reached during some of the manoeuvres carried out in the course of installation and if necessary set a value about 15 20 percent points higher in the parameter menu 15 7 AUTOSET MENU autoset Allo...

Page 17: ...erned In the case where a release knob with personalised key is fitted fig 18 proceed as follows Insert the personalised key in the lock and rotate the key anti clockwise Grip the release knob and rot...

Page 18: ...1 max 99 Fast opening time value expressed in seconds default 15 15s min 1 1s max 2 2 min Fast closing time value expressed in seconds default 15 15s min 1 1s max 2 2 min Slow down numerical value de...

Page 19: ...adio control device QR PR FGBBCL SRRML PCJC QC BCQGPCB SRRML 0 0 OK OK OK 0 1 R 06 OK OK OK OK RADIO MENU ADD Allows you to add one key of a radio control device to the receiver memory after storage i...

Page 20: ...8 249 mm 5 1 131mm 4 6 118 mm 6 2 160mm 10 4 265 mm 4 8 122 mm 1 9 50 mm 0 8 2 2 m m 1 7 4 3 m m Min 3 9 100mm Z14 Z 1 4 p 2 2 5 6 m m 0 9 25mm Min 2 9 75mm AXI PIGNON RITZELACHSE CENTRO PINON CENTRO...

Page 21: ...m 1 2 32mm 1 1 28mm 0 8 22mm 0 8 22mm DX SX Min 1 9 50mm NO OK push the control button or use the emergency relase In the event a person is trapped under the door Always keep a closing door within sig...

Page 22: ...2 S 24V 25W Max M 19 20 NO NO FAULT COM PED 21 22 23 24 25 26 COM 5 NC SWC NC SWO 24V JP2 JP3 JP1 0V 1 2 3 4 6 7 9 10 12 13 11 8 14 15 16 17 18 ANT Grigio Grey Gris Grau Gris Cinzento Grigio Grey Gris...

Page 23: ...te Contactos Contatos Contatti Contacts Contacts Kontakte Contactos Contatos 1 3 4 1 2 2 3 4 P1 P1 T1 Led T2 P1 P1 T1 T2 T3 T4 P1 P1 T1 Led T2 P1 P1 T1 T2 T3 T4 P1 P1 UNIFLAT UNIFLAT UNIMITTO UNITRC U...

Page 24: ...24 21 35 36 13 12 13 12 13 12 13 12 13 12 13 12 13 12 24 21 35 36 38 39 37 21 18 40 21 18 37 Rx 2 Rx 1 Tx 2 Tx 1 1 2 3 4 5 1 2 1 2 1 2 3 4 Rx 4 Rx 3 Tx 4 Tx 3 1 2 3 4 5 5 5 1 2 1 2 1 2 3 4 Rx 3 Tx 3...

Page 25: ...SCS1 SCS1 Max 250m TX1 TX2 RX1 RX2 TX1 TX2 RX1 RX2 TX1 TX2 RX1 RX2 SCS1 QSC D UL Fig 20A TX1 TX2 RX1 RX2 35 36 37 38 35 36 37 38 STOP SWO1 CC1 21 22 23 24 7 25 26 NC PHOT NC NC SWC1 6 NC SWO2 CC2 21 2...

Page 26: ...26 DEIMOS BT UL Ver 07 D811419_07...

Page 27: ...DEIMOS BT UL Ver 07 27 D811419_07...

Page 28: ......

Reviews: