MediPac, Tank-Feed Operator Manual
SYSTEM MAINTENANCE, Automatic Control Valves
Set Time of Day:
1.
Open the automatic control valve cover.
2.
Press and hold the
Red Button
in to disengage the drive gear.
3.
Turn the
Large Gear
until the actual time of day is opposite the time
of day pointer.
4.
Release the
Red Button
to engage the drive gear.
Set on Which Days to Regenerate/Backwash:
1.
Open the automatic control valve cover.
2.
Rotate the
Skipper Wheel
until the number is equal to the day being set, at the red pointer.
1=Monday, 2=Tuesday, 3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday, 7=Sunday
3.
Set the days that regeneration/backwash is to occur by sliding the tabs on the
Skipper Wheel
outward to expose trip f
ingers. Each tab is one day. Trip finger on the red pointer is “tonight”.
4.
Moving clockwise from the red pointer, extend or retract the trip fingers to obtain the desired
schedule.
Initiate a Manual Regenerate/Backwash:
1.
Open the automatic control valve cover.
2.
Turn the
Manual Regeneration Knob (
black-center
)
clockwise.
3.
This knob will make one revolution in approximately three hours.
4.
Even though it takes three hours for this knob to complete one revolution, the
regeneration/backwash cycle of your unit might be set for only one half of this time.
5.
In any event, conditioned water may be drawn after rinse water stops flowing from the drain
line.
Large
Gear
Manual
Regeneration
Knob
Red
Button
Skipper
Wheel