Better Water LLC; rev. Jun 2016
Page 27 of 72
MediPac, Tank-Feed Operator Manual
VALVES LEGEND and OPERATION
1.
Blend-Valve By-pass Valve
Open to bypass the Blend Valve
* CLOSED during normal operation
2.
City Boost Pump Inlet Valve
Open to allow water into the City Boost Pump
* OPEN during normal operation
3.
City Boost Pump By-pass Valve
Close to bypass the City Boost Pump
* CLOSED during normal operation
4.
Water Softener Inlet Valve
Open to allow water into Water Softener
* OPEN during normal operation
5.
Water Softener By-pass Valve
Open to bypass the Water Softener
* CLOSED during normal operation
6.
Water Softener Outlet Valve
Open to allow water to exit from the Water Softener
* OPEN during normal operation
7.
Worker Carbon Tank Inlet Valve
Open to allow water into Worker Carbon Tank
* OPEN during normal operation
8.
Worker Carbon Tank Outlet Valve
Open to allow water to exit from the Worker Carbon Tank
* OPEN during normal operation
9.
Polisher Carbon Tank Inlet Valve
Open to allow water into Worker Polisher Tank
* OPEN during normal operation
10.
Polisher Carbon Tank Outlet Valve
Open to allow water to exit from the Polisher Carbon Tank
* OPEN during normal operation
11.
Pre-Treatment UV Light Inlet Valve
Open to allow water into Pre-Treatment UV Light
* OPEN during normal operation
12.
Pre-Treatment UV Light By-pass Valve
Open to bypass the Pre-Treatment UV Light
* CLOSED during normal operation
13.
Pre-Treatment UV Light Outlet Valve
Open to allow water to exit from the Pre-Treatment UV Light
* OPEN during normal operation