![BETTCHER INDUSTRIES 1000M2 Operating Instructions And Spare Parts Lists Download Page 38](http://html.mh-extra.com/html/bettcher-industries/1000m2/1000m2_operating-instructions-and-spare-parts-lists_2743094038.webp)
TECHNICAL
BETTCHER
LARGE MODULAR SERIES II WHIZARD
MANUAL
INDUSTRIES, INC.
REV. June 28, 2012
Page 32
9.2 Daily Inspections & Maintenance (Continued)
Drive End Assembly Inspection And Replacement
Removal of the driver assembly
With one hand, pull the spring (#1) back to expose the knurled cap (#2) at the end of the tube.
Using the other hand, grip the knurled cap (#2) with a pair of pliers.
Using a 7/16” open end wrench, hold the flats on the drive end assembly (#3) and turn the knurled cap
(#2) counterclockwise.
Unscrew the knurled cap (#2) until the threads are free from the tube.
Pull the driver assembly (#4) out of the tube.
NOTE: Never
use pliers on the tube as damage to the internal parts may occur.
Inspection of the driver assembly (See Figure Below)
Wipe off excess grease.
Inspect the split bearing (#5) for wear or damage. Replace if required.
Slide the knurled cap (#6) forward against the driver (#7).
Wiggle the bushing (#8) sideways to check for excessive movement. Movement
should be minimal.
Slide the bushing (#8) and washer (#9) forward
toward the driver (#7). If the gap is 1/16” or
greater, the driver should be replaced.
Check the coupling cross pin (#10). If there is any free play or movement, replace the driver
assembly.
1
2
3
4
5
7
6
8
10
9