![BETTCHER INDUSTRIES 1000M2 Operating Instructions And Spare Parts Lists Download Page 32](http://html.mh-extra.com/html/bettcher-industries/1000m2/1000m2_operating-instructions-and-spare-parts-lists_2743094032.webp)
TECHNICAL
BETTCHER
LARGE MODULAR SERIES II WHIZARD
MANUAL
INDUSTRIES, INC.
REV. June 28, 2012
Page 26
9.1 Disassembly Of Handpiece (Continued)
Removal Of The Bearing From The Frame :
The bearing is pulled out from the
front of the tool.
Use a screwdriver to reach into the
bearing and catch the bearing
grease
groove.
While pulling upward, try to rotate
the bearing back and forth. Since
the bearing is not a press-fit, this
will work in most cases.
If the bearing will not come out, it
may be necessary to run a tap
into the bearing and pull on the
tap. If this is done, then the
bearing must be replaced due
to
damage.
The handpiece is now completely disassembled except for the cover retaining screws and
finger guard.
NOTE:
The cover retaining screws do not normally need to removed. If they do need to be
removed, turn the screw while pulling down to engage the thread in the frame.
Bearing
Finger Guard
(For Models 750M2 -1880M2 Only)
Cover Retaining Screws
Summary of Contents for 1000M2