9.2 Daily Inspections & Maintenance (Continued)
Casing Replacement
When the casing needs to be replaced, the drive end assembly may be retained and reused.
Hold the casing (#1) in a vise.
Unscrew the drive end assembly (#4) by turning counterclockwise using the wrench flats on the drive
end assembly.
Unscrew and remove the nylon washer (#3), casing latch collar (#2) or lever mounting collar (#5)
from the casing.
Discard the casing but retain and reuse the drive end assembly (#4), the nylon washer (#3),
the casing latch collar (#2) – or the lever mounting collar (#5) and disconnect lever (#6).
To Reassemble the Drive End Assembly to a New Casing
If using the casing disconnect, place the disconnect lever (#6) onto the lever mounting collar (#5).
Slip the casing latch collar (#2) or lever mounting collar (#5) with disconnect lever (#6) onto the new
casing.
Thread the nylon washer (#3) onto the new casing.
Clean the threads of the new casing assembly and apply Loctite #242 Threadlocker or equivalent.
Screw the drive end assembly (#4) on the new casing.
Tighten by hand and then with a wrench while holding the casing by hand.
NOTE:
DO NOT
hold the new casing in a vise or use pliers as
damage will occur. It is not necessary to over-tighten this joint.