TROUBLESHOOTING
TROUBLESHOOTING TABLE
SYMPTOM
POSSIBLE CAUSE
Knife motor will not start.
1.
No power to slicer.
2.
Keypad malfunction.
3.
Thermal switch open.
4.
Motor malfunction.
Slicer will not shut off.
1.
Keypad malfunction.
2.
Control board malfunction.
Hard to slice.
1.
Dull knife.
2.
Adjustment screw binding on square rail.
3.
Oil wick not properly lubricated.
Wedged shaped slices.
1.
Gauge plate not properly adjusted.
2.
Product not stable in product table.
Noisy.
1.
Bearing malfunction.
2.
Oil wick not properly lubricated.
3.
Motor malfunction.
4.
Belt mis-aligned.
Noisy in automatic mode.
1.
Belts not properly tensioned.
2.
Belts worn.
3.
Auto motor malfunction.
Knife motor running, knife not turning.
1.
Knife belt malfunction.
2.
Knife hub assembly malfunction.
Knife running or starting at less than
rated RPM (slow).
1.
Motor malfunction.
2.
Drive belt malfunction.
3.
Bearing malfunction.
Automatic slicing not engaging.
1.
Product table not properly seated.
2.
Flex cable damaged/ disconnected.
3.
Slide bar switch out of adjustment/ malfunction.
4.
Carriage sensor malfunction.
5.
Magnet on auto clip arm misaligned.
6.
Auto belt malfunction.
7.
Keypad malfunction.
8.
Control board malfunction.
9.
Auto motor malfunction.
X13 SLICER - TROUBLESHOOTING
F25332 Rev. A (0718)
Page 36 of 36