Translated user manual (EN-V1)
BENOMIC S500
53 / 57
Remark
Check how many battery chargers you can connect to one circuit. You can check this by
multiplying the number of amperes of the fuse with the voltage. E.g.: 16 A*230 V =3680 W
Subsequently check the battery charger power rating. Divide the total power by the battery
charger's power. E.g.: 3680/500=7.36. In this case, seven battery chargers can be
connected.
Also check that the voltage at the charging location corresponds with the voltage indicated
on the battery charger. There may be voltage loss with long cables. If this is the case, you
should consult your installer.
Check that it is the correct charger for your machine. The battery specifications that can
be used with the charger are indicated on the charger or in the user manual!
Substance Batteries wet, filled with acid, electrical storage
UN Number 27
HIN 80
ADR Label 8
ADR Class 8
Packing group -
Emergency Response Information
CORROSIVE SUBSTANCE
1. Characteristics
• Corrosive, causing damage to skin, eyes and air passages
• Not flammable
2. Hazards
• Heating of container(s) will cause pressure rise with risk of bursting and subsequent
explosion (BLEVE).
• Gives off corrosive and irritant fumes, also when burning
• May attack metals and produce hydrogen gas which may form explosive mixture with air
• The vapour may be invisible and is heavier than air. It spreads along the ground and
may enter sewers and basements
3. Personal protection
• Chemical protection suit.
• Respiratory mask equipped with ABEKP1 filter