Translated user manual (EN-V1)
BENOMIC S500
36 / 57
8.4.1
Use of the locking pins
After sliding out the stabilizers, the 2 locking pins must lock by being fully clicked into a
hole of the stabilizer post, see pictures below.
Fig. 8.5; Fixing locking pin WRONG and PROPERLY in locking hole
8.4.2
Locking the stabilizers in ‘out’ position
Unlock the blocking pins of the stabilizers (A). Slide the posts vertically downwards (B)
until the stabilizers are positioned on the ground. Check if the stabilizer feet are rotated
into horizontal position! Make sure both stabilizers are extended and the locking pins (C)
are locked into a locking hole according to (Fig. 8.5). The locking pins must lock into the
locking hole! Turn the handwheels (D) causing the stabilizers to move downwards to the
ground. Turn both handwheels until the BENOMIC S500 is stable and horizontal (Fig.
8.6). Repeat these actions for the other side of the pipe rail trolley. To work higher than
the listed restrictions* (10.1) is only possible if all four stabilizers have sufficient bearing
capacity on the ground.
Fig. 8.6; Overview of stabilizers extracted
When the stabilizers are extended and are on the ground with load bearing
capacity, the BENOMIC S500 can no longer drive and the working platform is
unlocked to rise above the restricted values* (10.1)!