Translated user manual (EN-V1)
BENOMIC S500
15 / 57
5.3
Signalling systems
In order to alert the user to changing status of the
BENOMIC S500
during use, a multi-
colour indicator (11) and horn are used.
5.3.1
The multi-colour indicator (11)
The multi-colour indicator (11) is located on the platform control, for this refer to chapter
8.1.2.
The visual signalling is divided into 7 indication levels:
1. Safe & alert status
Colour Green or Orange
2. Acute danger
Colour Red
3. Indirect danger
Colour Red-Orange
4. Function monitoring (sensors)
Colour Red-Blue
5. Reset emergency stop
Colour Blue
6. Cruise control
Colour Light-Blue
7. Disinfection
Colour Purple
Safe & alert status
The indicator displays a status or flash pattern in the colours Green or Orange
Green
:
Safety status:
Limitation:
Solution:
Off
Benomic S500 is
powered off
Is off
On
BENOMIC S500 is
on, in safe status
None
Flashing
2x
Start-up / standby,
flash indicates the
number of scissors
Is on standby
Press horn / reset button (2 or
10)
Stops automatically
Flashing
3x
Start-up / standby,
flash indicates the
number of scissors
Is on standby
Press horn/reset button (2 or 10)
Stops automatically
Flashing
4x
Start-up / standby,
flash indicates the
number of scissors
Is on standby
Press horn / reset button (2 or
10)
Stops automatically
Orange
:
Safety status:
Limitation:
Solution:
Flashing
bleeping
Tilt warning
“attention” with
raised platform
level the pipe-rail system (see
7.3)