Multifunction Control Panel
wires) will signal open Alarm/Tamper contacts.
z
Balance 10k (BAL)
-
(Balance 1k2 for Kyo16D)
In Standby status, the
zone must be connected to Negative by a 10K
Ω
(or 1.2Kohm for
Kyo16D).
For ‘Vibration’ or Roller Blind’ zones attribute, the resistor is
1.5K
Ω
(or 600 ohm for Kyo16D)
. If the resistor is short
-
circuit
ed, the
Control panel will generate a Tamper Alarm. If the resistor disconnects
(Zone Open), the Control panel will generate an Alarm event.
z
Normally Closed (NC)
- In Standby status, the Zone must be connected
to Negative. The Control panel will generate an Alarm when the contact
opens.
A
If Zones are programmed as Normally Closed, the Performance level
of the Control panel will down-grade from Level II to Level I — as the Zones
concerned will not be protected against short-circuit.
z
Normally Open (NO)
- In Standby status, the zone must be Open. The
Control panel will generate an Alarm when the Zone connects to Negative.
A
The IMQ-SECURITY SYSTEM Certification does not apply when
Zones are programmed as Normally Open, as the zones concerned will not
be protected against wire cutting.
z
Doubled
(Only for KYO16D) - This balance type is used to double the
zone. In this way every line (from L1 to L6) can manage two different
devices (for example, 2 sensors or 1 sensor and 1 contact) and the Control
Panel is able to recognize the one or the other in case of alarm.
z
Doubled EOL
(Only for KYO16D) - As the precedent, but it needs a series
End-Line (EOL) resistor of 1.2 Kohm to detect short circuits.
Attributes
z
Unbypassable (Not Byp.)
- Zones with this attribute cannot be bypassed.
z
Chime (Chime)
- Violation of a zone with this attribute, during
Disarmed
status of its Partition, will generate an audible signal on Keypads and
PROXI readers with the ‘Chime’ attribute (refer to ‘Chime on Keypad’ and
‘Chime on Proxi Reader’ on the
‘Options’ page). Violation of a ‘Chime’
zone, during
Armed
status of its Partition, will not generate an audible
signal.
z
Test (Test)
- Zones with this attribute will be operative, however, violation
will not activate the audible-visual signalling devices or the Communicator
but will be recorded in the event buffer.
Zones with this attribute will
always operate as “Instant” Zones, even if they have been programmed as
“Delayed” Zones.
z
Mute (Mute)
- Violation of a zone with this attribute will activate the
Communicator only. The audible-visual signalling devices and the keypads
and PROXI Readers will remain silent.
z
Internal (Internal)
- Zones with this attribute will be bypassed when
their Partitions are armed in ‘Stay’
mode (S) or
‘Stay 0 Delay’
(I).