69
®
®
Section 3 - Programming from PC
*//"!
Contact
ID Code
No.
Event
Description
Occurs when ...
Kyo4-8
Series
Kyo
16D
Kyo32
Series
45
00...03
00...03
00...07
Alarm
on Partition n°
... alarm conditions are detected on one of the zone
assigned to Partition n°
45)
04...11
04...19
08...39
Alarm on Zone n°
... alarm conditions are detected on Zone n°
45
12...15
20...23
40...47
Inactivity Partition n° ... the Control panel detects Inactivity on Partition n°
45
16...19
24...27
48...55 Negligence Partition n° ... the Control panel detects Negligence on Partition n°
45)
20...27
28...43
56...87
Bypassed Zone n°
... Zone n° is bypassed
45)
28...35
44...59
88...119 Unbypassed Zone n° ... the Zone n° is unbypassed
45
36...59
60...100 120...143 Recognized Code n°
... the Code n° is recognized.
For CONTACT-ID, the User ID (CCC) ranges from 1 to 24
to specify the corresponding Recognized Code.
45
60...187 101...228 144...271 Recognized DGK n°
... the Key/Card n° (SAT or PROXI-CARD) is recognized.
For CONTACT-ID, the User ID (CCC) ranges from 25 to 152
to indicate the Recognized Key number
(e.g. Key 1 - CCC=25, Key 128 - CCC=152).
45)
188...195 229...244 272...303
Auto-bypass
Zone n°
... the Zone n° is unbypassed automatically
(refer to 'Options Page')
45)
196...199 245...248 304...311
Arm Partition n°
... the Partition n° is armed by Code or Key/Card
45)
200...203 249...252 312...319
Disarm Partition n°
... the Partition n° is disarmed by Code or Key/Card
45
204...207 253...256 320...327
Special
Arming
Partition n°
... the Partition n° is armed via:
a) a Command Zone
b) the Scheduler
c) the PC on-line
45
208...211 257...260 328...335
Special
Disarming
Partition n°
... the Partition n° is disarmed via:
a) a Command Zone
b) the Scheduler
c) the PC on-line
45
212...215 261...264 336...343
Reset Memory
Partition n°
... the Alarm Memory of thePartition n° is deleted
45
216...219 265...268 344...351
Duress Partition n°
... a Duress Code is used to disarm the Partition n°
45
220...227 269...276 352...359
Failed Call n°
(Description)
... the call to theNumber (1 ... 8) is unsuccessful.
Failed Call Events 220 (352) to 227 (359) cannot be programmed
to generate calls to their assigned telephone numbers. For
example, Failed Call Event 220 (352) cannot be programmed to
generate a call to Tel. Number 1, as this would generate a series
of Failed Calls to this Tel. Number.
45
228...235 277...292 360...391
Tamper
Zone n°
... tamper conditions are detected on the Zone
(occurs only when the terminals of Balance
or Double Balanced Zones are shorted)
45)
236...243 293...308 392...423
Restore Zone n°
... the Zone is restored after an Alarm or after a Tamper event
45
244
309
424
BPI Tamper
... tamper is detected on one of the BPI devices
(Snatch or forced opening)
45
245
310
425
Restore BPI Tamper ... all the conditions that generated the BPI Tamper event cease