16
Multifunction Control Panel
®
®
if you enter an incorrect address, wait at least 1 second before trying again.
On the LCD keypad, the address that has been set is shown by the last two char-
acters of the top line of the display.
On the LED Keypad, the address set is shown by LEDs 1 to 16.
During all the steps involved in programming, the bottom line of the LCD Keypad
display shows all the keys which can be used at any given time.
NOTE - Every time a keypad which has already been programmed is pow-
ered, a keypad tamper alert will be generated.
Programming the LCD Keypad
For programming the LCD Keypad, follow the procedure described below.
1)
Press and keep pressed the keys 1 and OFF for at least 3 seconds after
which the programming phase starts: the display will show in the first line the
name of the keypad (PREMIUM) and the actual address (for example, 1).
2)
Programming the ADDRESS - Set the address of the keyboard (from 1
to 8), then press ENTER to confirm the appearing address and move on to
the next step or press ESC to cancel the change and exit programming.
3)
Programming the Proximity Reader - Press ON to enable the Proximity
Reader, then set the address of the Proximity Reader (from 1 to 16), then press
ENTER to confirm and move on to the next step or, press OFF to disable the
Proximity Reader, then press ENTER to confirm and move on to the next step
or, press ESC to cancel the changes and return to the preceding step.
4)
Programming the INPUT EXPANDER - Press ON to enable the Input
Expander, then set the address of the Input Expander (from 1 to 4) then press
ENTER to confirm and move on to the step no.
6)
or, press OFF to disable
the Input Expander, then press ENTER to confirm and move on to the next
step or, press ESC to cancel the changes and return to the preceding step.
NOTE – If the Input Expander function is enabled, every time the keypad
is connected to the power supply, an Input Expansion tampering signal
will be generated, in addition to the normal device disconnection mes-
sages.
The zones corresponding to terminals L4, L5 and L6 of the Keypad Input
Expander, although appearing on the application/display, CANNOT be
used.
5)
Programming the OUTPUT EXPANDER - Press ON to enable the
Output Expander, then then set the address of the Output Expander (from 1 to
2) then press ENTER to confirm and exit programming or, press OFF to
disable the Output Expander, then press ENTER to confirm and move on to the
next step or, press ESC to cancel the changes and return to the preceding step.