Section 3 - Programming from PC
The Card/Key Readers will allow you to perform all basic operations, such as:
Global Arming
Disarm Partitions
A Mode Arming
B Mode Arming
Stop Alarm on Partitions
Readers Table
This window will allow you to enable (
) or disable (box empty) the system Read-
ers (see Figure).
No. - This column shows the Reader Address (non-editable).
Description - This field is for the Reader label (maximum 16 characters).
1 2 3 4 5 6 7 8 - These columns correspond to the 8 partitions. The Readers can
be programmed to operate in 3 different modes on the 4 partitions, as follows.
RED - This row will allow you to enable (
) or disable (box empty) the
Reader for GLOBAL Arming on the selected partitions (see Figure). All the
enabled partitions will arm, when the PROXI CARD/Key is removed from
the Reader when the RED LED is ON.
AMBER - This row will allow you to enable (
) or disable (box empty) the
Reader for A Mode Arming on the selected partitions. The partitions will
Arm or Disarm, as programmed, when the PROXI CARD/Key is removed
from the Reader when the AMBER LED is ON. Refer to table 3.1 for the
A Mode programming instructions.