56
Multifunction Control Panel
®
®
z
System Tamper (Sys Tamp) - The Output will activate when violation is
detected on the 24h Tamper line, or when the Control panel is forced open.
The Output will restore automatically when the Alarm cycle ends.
z
BPI Tamper (BPI Tamp) - The Output will activate when Keypad tamper
is detected (when the keypad, PROXI or Expander frontplate is removed).
The Output will restore automatically when the Alarm cycle ends.
z
Valid Key/Code (Key) - The Output will activate when the Control panel
recognizes a valid Key/Card, and will remain active until the ON Time ex-
pires. This signal can be associated with ‘Monostable’ Outputs only.
z
Missing BPI (Missing) - The Output will activate when an enrolled BPI
device fails to respond to the Control panel.
z
Superkey 2 (Key 2) - The Output will activate when the ‘Superkey 2’
facility is requested via Keypad. This signal can be associated with
‘Monostable’ Outputs only.
z
Superkey on wireless key (Key2 WLS) - The Output will activate when
the ‘Superkey 2’ facility is requested via Wireless Key. This signal can be
associated with ‘Monostable’ Outputs only.
Partitions
This section will allow you to assign the Outputs to the Partitions. The Output will
activate when the programmed signal is generated by one of its Partitions.
When the signal is generated by the Control panel (e.g. Trouble), the Output
will activate directly, and its Partitions will not be influent. In all other cases,
the Output will activate only when the signal is generated by one of its Parti-
tions.