18
Multifunction Control Panel
®
®
4)
Programming the INPUT EXPANDER - The lit LED
G
indicates that
the Input Expanderis being programmed.
Press ON to enable the Input Expander, then program the address which you
would like to assign to the Input Expander (from 1 to 4), then press ENTER to
confirm and move on to the step no.
6)
or, press OFF to disable the Input
Expander, then press ENTER to confirm and move on to the next step or,
press ESC to cancel the changes and return to the preceding step.
NOTE – If the Input Expander function is enabled, every time the keypad
is connected to the power supply, an Input Expansion tampering signal
will be generated, in addition to the normal device disconnection mes-
sages.
The zones corresponding to terminals L4, L5 and L6 of the Keypad Input
Expander, although appearing on the application/display, CANNOT be
used.
5)
Programming the OUTPUT EXPANDER - The lit LED
V
indicates
that the Output Expander is being programmed. Press ON to enable the Out-
put Expander, then program the address which you would like to assign to the
Output Expander (from 1 to 2), then press ENTER to confirm and exit from
programming or, press OFF to disable the Output Expander, then press EN-
TER to confirm and move on to the next step or, press ESC to cancel the
changes and return to the preceding step.
The outputs corresponding to terminals OC4, OC5 and OC6 of the Keypad
Output Expander, although appearing on the application/display, CAN-
NOT be used.
It is possible to enable ONLY ONE of the two Espanders: either the Input
or the Output Expander. If you do not want to use any Expander, put in
the value OFF for both of them.
6)
Programmazione of the ZONES - The lit LED
T
,
S
,
X
and
P
indicate
that the functioning mode of the zone is being programmed.
LEDs 1, 2 and 3 show the programmed operating mode, respectively for the
zones corresponding to terminals T1, T2 and T3:
LED lit = normal operating mode (NORM);
LED flashing = normal operating mode + interface for roller blinds (FAST).
Programming of Zones
NORM
The zone functions in Normal Mode
FAST
The zone functions in Normal Mode and as Contact Interface for Roller
Shutter, or rather, it sounds the alarm according to the programmed
Sensitivity or if 5 tight pulses are detected, within 2 minutes.
Press keys 1, 2 or 3 to change, respectively, the operating mode of the zones
corresponding to terminals T1, T2 and T3:
Summary of Contents for KYO 32 P