Multifunction Control Panel
®
®
Memory function
Walk-Test mode
Special features
Alarm Detectors
The Control panel provides 8 independent zone terminals (4 on KYO4,
6 for
Kyo16D
): [L1], [L2], [L3], [L4], [L5], [L6], [L7], [L8] which accept Normally
Closed and Normally Open detectors. The 10 K
Ω
resistors (
1.2 K
Ω
for Kyo16D
Control Panels
)
will allow you to set up the zones as Balanced or Double Balanced.
Resistors are not required when the lines are programmed as N.C. or N.O.
Negative terminal [
M
M
M
M
M
] and Positive terminal [+B] (or [+F] on Series G models)
can be used to power the detectors. Several detectors can be connected to each
zone, however, one detector per zone is recommended. Figures 2.4, 2.5 and 2.6
show several wiring solutions.
Some detectors provide special features, such as the Memory function and
Walk-Test mode.
The Memory function is useful when several detectors are connected to the
same Alarm line (see Figure 2.7) as, in the event of an Alarm, it will allow you to
trace the violated zone.
The Walk-Test mode will enable the LED for test purposes. The Walk-Test
mode should not be enabled during standby status as, in the event of violation,
the LED will turn ON thus warning intruders of their detection.
Both functions can be enabled by a Positive or Negative signal, depending on the
detector. The Wiring diagram in Figure 2.7 shows three Bentel LB612 detectors
with Memory function (terminal [AB]) which will be activated by a Positive
signal. In a connection of this type, one of the three OC outputs (see terminal
[O1]) must be programmed to disable the Walk Test mode during standby status.
Figure 2.4 - Connecting detectors to N.C. (
a
) and Balanced lines (
b
)
To Tam p er Lin e
1 0 K
To Tam p er Lin e
b
a
+B
+F
+B
+F
+B o n K Y O 4-8-8W -3 2 m o de ls
o n K Y O 8G -8 G W -32G m o dels
o n K Y O 16 D m o del
+F
+V AUX
1,2K o n K Y O 16 D m o del