57
111660 Rev C 5-13-14
Diagnostic Code 5 - Pump Handle Test
To enter this test, enter diagnostics and press the 5 button
on the keypad and the ENTER button.
This test checks the status of the pump handles on the
dispenser. The CPU reads the pump handle switches
and writes the status of each handle to the display.
When all handles are off, the display appears as in figure
D-9a. When a handle is turned on, an A or b should
appear. See figure D-9b for an example of the A pump
handle raised.
Turn each pump handle on individually or all at once to
test the status.
Press
CANCEL
button to exit this test. Press the
CANCEL
button twice to exit Diagnostics.
HAndLE
Figure D - 9a
dIAg
5
HAndLE
A
Figure D - 9b
dIAg
5
How to Use Diagnostics