37
111660 Rev C 5-13-14
How To Select the Fleet Option
Menu Code 15
NOTE: This menu code only applies to dispensers connected to a fleet system interface.
This menu (when enabled) will allow a price change after the pump handle has been turned on. This
allows the dispenser to be compatible with fleet systems for use in non-retail situations. The dispenser
may not be compatible with the fleet system interface if this option is not enabled. The fleet option is set
as enabled as a default. The options are:
0 - the fleet option is disabled
1 - the fleet option is enabled (this is the default)
To select a different option in Menu Code 15, follow this
procedure:
1. After the Manager’s Mode has been accessed, press
the number 1 and 5, then the
MODE
button on the
keypad. The price display shows the dispenser is in
Menu Code 15.
If the dispenser has not been programmed since it
came from the factory, the number 1 appears in the
main display. See Figure 15.1. This is the default
setting.
2. To disable the fleet option, press the 0 button on the
keypad to enter.
NOTE: If an error is made, press the correct number.
The new number replaces the error.
3. When the correct option number appears in the main
display, press the
ENTER
button to save the
selection.
4. Press the
CANCEL
button to exit this menu code.
5. If this is a two sided dispenser, changing one side will
automatically change the second side to the same
value as the first.
FLEEt
1
Figure 15.1
COdE
15
How to Program the Dispenser for Operation