16
111660 Rev C 5-13-14
How to Retrieve the Last Sale During a Power
Failure:
If an A.C. power failure occurs, the dispenser can display
the last sale in progress at the time of the failure as well
as money and volume totals.
To read the last sale in progress, follow this procedure:
1. Hold the black Access Magnet over the “Sale $” print
beside the Main Display. See Figure T-10
The last sale in progress is displayed for 30 seconds.
Record the last sale information.
2. To redisplay the last sale information after the timer
has turned the display off, hold the black Access
Magnet over the “Sale $” print again.
NOTE:
The battery will display data for thirty
seconds. To restart the timer after the
dispenser has turned off, hold the black
Access Magnet over the “Sale$” print.
0.00
0.000
Reed Switch for the
Last Sale Recall
Access Magnet
Figure T-10
How to Operate the Dispenser