50
111660 Rev C 5-13-14
How to Perform a RAM Clear
Menu Code 49
Sometimes it may be necessary to perform a “RAM Clear” procedure. This is a procedure that should
only be done after all other logical troubleshooting steps have been exhausted. It is used sometimes if
the dispenser software stops operating. Or, if the main memory gets “corrupted” or “filled with garbage”.
This procedure will clear the memory.
To clear the RAM in mode 49, follow this procedure:
1. After the Manager’s Mode has been accessed, press
the number 4 and 9, then the
MODE
button on the
keypad. See figure 49.1.
2. To perform the RAM Clear you must hit the 1 button
then
ENTER
. At this point the display will says, “COLd
StArt” for approximately 45 seconds. See figure 49.2.
3. After 45 seconds the display will act like you just
plugged in the manager’s keypad for the first time.
See figure 49.3. You will have to re-enter the
password in Mode 03 before proceeding.
Caution -
Some dispenser programming may be lost after
the RAM Clear and system reprogramming will be
required.
Caution -
This procedure will zero out electronic pump
totals.
Caution -
Do not show your customer how to do this
procedure. This procedure should only be performed by
factory trained personnel.
Note :
The RAM Clear procedure is not a warranted
procedure unless Technical Support is contacted and
recommends it.
CLEAr
dAtA 0
Figure 49.1
COdE
49
COLd
StArt
Figure 49.2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
EntEr
SidE 1
Figure 49.3
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
How to Program the Dispenser for Operation