How To Set a No Flow Time Out
Menu Code 9
As a safety feature, the dispenser can be programmed to turn off if no flow occurs within a specific
amount of time. If the pump handle is turned on, but no flow occurs, the No Flow Time Out feature
prevents delivery after the time period you programmed expires. If the pump handle is turned on and
flow occurs, but is stopped, the No Flow Time Out feature prevents delivery after the period of time
programmed has elapsed.
The No Flow Time Out feature is programmable from 0 seconds to 999 seconds (16.6 minutes or an
infinite amount of time represented by - - -). The dispenser is shipped from the factory with Menu Code 9
disabled (infinite time).
To program the period of time before the No Flow Time
Out turns off the dispenser or to disable Menu Code 9,
follow this procedure:
1. After the Manager’s Mode has been accessed, press
the 9 button and then the
MODE
button on the keypad.
The main display on an un-programmed dispenser will
appear as in Figure 9.1. This is the default. The price
display shows the dispenser is in Menu Code 9.
The three dashes indicate the No Flow Time Out
amount is an infinite amount or that Menu Code 9 is
disabled. With this setting the dispenser’s valves will
remain on indefinitely after the pump handle lever is
put in the
ON
position and the dispenser is authorized.
2. Use the 0 through 9 buttons on the keypad to enter a
Flow Time Out value in seconds. For example, if a 20
second delay is entered, the volume display window
looks like Figure 9.2.
NOTE: If an error is made, press the 0 button until all
three digits are zeros and enter a new number,
or push number buttons until the correct
number of seconds appears in the volume
display.
3. When the correct value appears in the volume display,
press the
ENTER
button to save the selection.
4. To disable Menu Code 9, press the
button on the
keypad (See Figure 9.3) and press the
ENTER
button.
The volume display returns to three dashes.
5. Press the
CANCEL
button to exit this menu code.
6. If this is a two sided dispenser, changing one side
will automatically change the second side to the same
value as the first.
NOTE: The no flow timer works with the dispenser in the
ready state (handle up and armed) and in the flow state
(handle up and at least .009 Gallons / Liters
dispensed).
Figure 9.3
nO FLO
- - -
Figure 9.1
COdE
9
nO FLO
020
Figure 9.2
COdE
9
How to Program the Dispenser for Operation