Bennett Pacific Series Operator'S Manual Download Page 1

  

111660 Rev C  5-13-14 

 

 

Bennett Pacific Series 

1000 Series Remote Dispensers

 

 

 

Operator’s Manual 

Only Trained Personnel May Work on This Equipment 

Includes Instructions For: 
Sales Operation 

Reading Totals 
Programming 
Diagnostics 

Maintenance 

For Pacific Dispensers Only 

 
READ THIS BOOK 

This book has important information for safe installation and 
operation of this equipment.  Read and understand this book 
before applying power.  Keep this book and tell all service 
personnel to read this book.  If you do not follow the 
instructions, you can cause bodily injury, death or damage to 
the equipment. 

For new books, FAX to: 

BENNETT MARKETING SERVICES 
 (231)799-6202

 

or visit our web page at: 

http://www.bennettpump.com

 

Bennett 1218 E. Pontaluna Road, Spring Lake, MI 49456

 

USA 800-235-7618 ~ Outside USA 231-798-1310  

[email protected] ~ www.bennettpump.com

 

Summary of Contents for Pacific Series

Page 1: ...for safe installation and operation of this equipment Read and understand this book before applying power Keep this book and tell all service personnel to read this book If you do not follow the instr...

Page 2: ...Octane Error Range 25 8 How to Change the Decimal Point Locations for Other than U S Standard 29 9 How to Set a No Flow Time Out 30 10 How to Set a Slow Flow Amount 31 11 How to Set a Volume Allocatio...

Page 3: ...c straps before working on the equipment WARNING To prevent electric shock keep the electrical parts of the dispenser dry WARNING You must have training in the installation service or maintenance of t...

Page 4: ...Local Preset with receipt printer Debit Credit Payment Terminal Vapor return piping connections for balance vapor systems Healy Vapor Recovery Junction Box Second field wiring conduit entry Valance ki...

Page 5: ...display information during a power failure 8 A second magnetic switch allows the attendant to read daily totals from the pump face This switch also gives you access to the Audit Trail 9 Two battery b...

Page 6: ...otals Once the totals mode is entered the next totals are displayed tapping the magnet over the Gallons Liters print beside the Main Display By successively tapping over the Gallons Liters print all t...

Page 7: ...e from the holder and lift the pump handle up for the ON position Push the pump handle down for the OFF position These are referred to as lift to start nozzle boots The Pump Handle See Figure 10 Push...

Page 8: ...n the spring presses against the lever at an angle that forces it open as you lift the nozzle The Grade Select Buttons See Figure 13 The customer must select the grade to be pumped before the dispense...

Page 9: ...fuel into the vehicle or approved container 5 Release the nozzle trigger when the desired amount of fuel has been dispensed 6 Lower the handle to the OFF position If the nozzle boot is set for auto on...

Page 10: ...the dispenser is a single hose dispenser a grade button must be pressed to start a sale NOTE If fueling doesn t begin within 60 seconds of starting the sale then the preset will reset to Full Tank 4 S...

Page 11: ...in whole unit gallon or liter increments See Figure D 5 Note Because of rounding methods used and the nature of electronic totals versus an analog device such as an electro mechanical totalizer electr...

Page 12: ...Product 1 Money Total Menu Code 1 2 To read the money totals for Hose 2 and the remaining hoses press the ENTER button or the number button for the hose 1 2 3 4 The display reads P 2 1 1 for Product 2...

Page 13: ...cedure 1 To enter the totals mode hold the black Access Magnet over the Gallons Liters print beside the Main Display See Figure T 6 for location When the first Money totals appear remove the magnet Th...

Page 14: ...peat steps 2 and 3 for the Product 2 to tals and the remaining hoses on this side of the dis penser 5 If all Menu Code 1 totals have been displayed tap the magnet over the Gallons Liters print again t...

Page 15: ...er is a blender follow this procedure 1 Press the 2 button and then the MODE button on the keypad The main sales display appears similar to Figure T 8 NOTE The number displayed is a grand electro mech...

Page 16: ...beside the Main Display See Figure T 10 The last sale in progress is displayed for 30 seconds Record the last sale information 2 To redisplay the last sale information after the timer has turned the...

Page 17: ...pad is properly connected the dispenser will automatically enter the managers programming mode The dispenser s display will read Enter side 1 5 When the programming session is complete remove the keyp...

Page 18: ...l placement for other than U S standard 9 No Flow Time Out Program to set a time for the dispenser to turn off after flow stops 10 Slow Flow Amt Program to control the slow down limit on a prepay sale...

Page 19: ...rder as they are listed in the Initial Setup sequence below Each Menu Code can be pro grammed individually However in order for the dispenser to operate properly the initial setup program ming sequenc...

Page 20: ...2 Enter the default number 2218 Four dashes appear in the display 3 Press the ENTER button When access is gained the dashes disappear and the price display appears as in Figure 3 2 If the dashes do n...

Page 21: ...E mode by unplugging the manager s keypad from the dispenser Then re enter the ATTENDANT mode by plugging the keyboard back in 2 Press ENTER for Side 1 3 Press the 3 button and then the MODE button on...

Page 22: ...er 1 When the first digit of the new price is entered the Main Display zeros and indicates the new digit in the right most digit The Price display continues to flash the old price See Figure 4 2 When...

Page 23: ...ical total The 5 means the dispenser is in Menu Code 5 The 1 stands for Side 1 2 Use the 0 through 9 buttons on the keypad to enter the new meter volume value from the mechanical totalizers When the f...

Page 24: ...ollow this procedure 1 Press the 6 button and then the MODE button on the keypad The main display shows the first setting which is how many Sides in Code 7 See Figure 6 1 Press ENTER and the display s...

Page 25: ...3 must be entered into the pump and the PPV display must indicate dashes before this mode may be entered 1 Press the 7 button and then the MODE button on the keypad The number 7 appears in the price d...

Page 26: ...ption press the 0 button and the main display now appears like Figure 7 5 8 To turn set it for the Mixer option press the 2 button and the main display now appears like Figure 7 6 on next page Note th...

Page 27: ...blend ratio For example To set a 40 60 blend ratio enter 40 To set a 30 70 blend ratio enter 30 NOTE If an error is made press the correct number The new number replaces the error 11 When the correct...

Page 28: ...s in the main display press the ENTER button to save the selection and figure 7 10 appears At this point you must enter either 1 or 2 for the number of tiers that will be used 16 When the correct opti...

Page 29: ...The price in Selection 0 is in dollars The price in Selection 6 is in cents DECIMAL PLACEMENT SELECTIONS MONEY VOLUME PPV DISPLAY DISPLAY DISPLAY Volume Selection Money Gallons Liters Price 0 1 23 1 2...

Page 30: ...indicate the No Flow Time Out amount is an infinite amount or that Menu Code 9 is disabled With this setting the dispenser s valves will remain on indefinitely after the pump handle lever is put in t...

Page 31: ...300 400 500 600 700 800 900 1 000 1 300 8 18 GPM 18 GPM or higher LITERS 1 2 3 4 5 6 7 8 9 10 30 68 LPM 68 LPM or higher How to Program the Dispenser for Operation To select a slow flow amount in gall...

Page 32: ...n on the keypad The price display shows the dispenser is in Menu Code 11 If the dispenser has not been programmed since it came from the factory the number 0999 appears in the main display This is the...

Page 33: ...rol valve turns on follow this procedure 1 After the Manager s Mode has been accessed press the number 1 and 2 then the MODE button on the keypad The price display shows the dispenser is in Menu Code...

Page 34: ...er s Mode has been accessed press the number 1 and 3 then the MODE button on the keypad The price display shows the dispenser is in Menu Code 13 If the dispenser has not been programmed since it came...

Page 35: ...display and cash price to the bottom display 1 FLIPPED The POS sends the the credit price to the bottom display and cash to the top display requiring FLIP to be turned on The Digit Option is used to...

Page 36: ...option Press ENTER to see the Dash option See Figure 14 2 This is the default setting for the Dash option Press ENTER to see the FLIP option See Figure 14 3 This is the default setting for the FLIP op...

Page 37: ...procedure 1 After the Manager s Mode has been accessed press the number 1 and 5 then the MODE button on the keypad The price display shows the dispenser is in Menu Code 15 If the dispenser has not be...

Page 38: ...Tax Receipt Printer is done with the use of a standard PC keyboard with a PS2 connector Unlock and gently open the electronic enclosure door Plug in the keyboard connector to the PS2 connector on the...

Page 39: ...method of calculation volume x PPV To select a different option in Menu Code 18 follow this procedure 1 After the Manager s Mode has been accessed press the number 1 and 8 then the MODE button on the...

Page 40: ...Manager s Mode has been accessed press the number 2 and 1 then the MODE button on the keypad The price display shows the dispenser is in Menu Code 21 If the dispenser has not been programmed since it...

Page 41: ...on the keypad The PPV display shows the dispenser in Menu Code 22 If the dispenser has not been programmed since it came from the factory the number 1 appears in the main display This is the default...

Page 42: ...ton is pushed The valves turn on as soon as the dispenser completes the reset cycle and the pre charge time is reached To select a different option in Menu Code 23 follow this procedure 1 After the Ma...

Page 43: ...for the dispenser is 7 890 123 45 the display appears as in Figure 26 1 The price display window reads P 1 1 d for Product 1 Money Total Menu Code 26 2 To read the money totals for Hose 2 and the rem...

Page 44: ...e Figure 26 5 If the dispenser is a blender Series The first product represents an unblended Product The middle product represents the blended total of the first unblended Product and the last unblend...

Page 45: ...en accessed press the number 2 and 7 then the MODE button on the keypad The first display shows the current electronic calibration correction constant of the first configured meter See figure 27 1 Use...

Page 46: ...ly change the amount to anegative value after the entered amount is other than zero Once the ENTER key is pressed the main display will show READY Go to step 3 to run another test can or press CANCEL...

Page 47: ...correction constant is entered it will show up in the main volume display When the ENTER button is pressed the entered electronic calibration correction constant is loaded into the current meter and a...

Page 48: ...programmed since it came from the factory the number 1 appears in the main display This is the default setting See Figure 28 1 2 To change the setting use 0 or 1 button on the keypad to enter a new op...

Page 49: ...ppears on the Money Volume Display 3 To advance to the next product hit the Enter button See figure 29 2 The top left price display shows 02 which tells you that it is displaying the totals for the vo...

Page 50: ...d StArt for approximately 45 seconds See figure 49 2 3 After 45 seconds the display will act like you just plugged in the manager s keypad for the first time See figure 49 3 You will have to re enter...

Page 51: ...et after 120 seconds of no communication You can set this from 5 seconds to 200 seconds 3 Press the numeric keys to enter the desired time for the reset 4 If you press the button then you will disable...

Page 52: ...r has not been programmed since it came from the factory then it will be set for the default The 0 if new or any other number which appears in the second row under the 1 is a counter It tracks the num...

Page 53: ...tware I D Number CKsum 1 Display Segment Test 4 RAM Test Diagnostic Code Description 6 2 Uart Failure Counter 6 3 Cold Start Counter 6 4 Reserved 6 5 Reserved 7 Keyboard Switch Beeper Test 6 1 Power F...

Page 54: ...3 appears The price display shows the dispenser is in Diagnostics Level 0 2 The current level of software installed in the dispenser is displayed which will change from version to version Press ENTER...

Page 55: ...he CANCEL button twice to exit Diagnostics Diagnostic Code 2 Error History The error log file provides 40 entries total The latest 40 errors are included in the error log file The errors are displayed...

Page 56: ...utton to exit this test Press the CANCEL button twice to exit Diagnostics Error 99 Figure D 7 dIAg 3 Diagnostic Code 4 RAM Test To enter this test enter diagnostics and press the 4 button on the keypa...

Page 57: ...d writes the status of each handle to the display When all handles are off the display appears as in figure D 9a When a handle is turned on an A or b should appear See figure D 9b for an example of th...

Page 58: ...NTER to advance to the next counter Communications Failure Counter This code is used to investigate intermittent problems with communications The counters keep track of the number of times a communica...

Page 59: ...he CANCEL button to exit this test Press the CANCEL button twice to exit Diagnostics Diagnostic Code 7 Keyboard Switch and Beeper Test To enter this test enter diagnostics and press the 7 button on th...

Page 60: ...can be displayed by pressing the i button Press the ENTER button to move forward through the log When all logged transitions have been viewed the display flashes the message shown in figure D 12c Pre...

Page 61: ...t and damage electronic components Keep the dispenser clean and protected It will keep a new pump appearance longer To clean painted surfaces follow this procedure 1 Wash the dispenser in a solution o...

Page 62: ...ional E mail intlsales bennettpump com www bennettpump com Contacting Bennett Pump Related Literature Part No Description 111102 Pacific Series Electronic Installation Manual 111660 Pacific Series Ope...

Page 63: ...terms and restrictions expressly set forth in a written agreement with PCI SSC or in an approval letter All other references to PCI SSC s approval are strictly and actively prohibited by PCI SSC When...

Page 64: ...e or abuse including substituting parts or accessories from other manufacturers without the written consent of Bennett Pump Company The above warranties shall not exist if the original identification...

Page 65: ...clusions 1 Warranty does not apply to any product which has been altered subjected to unusual physical or electrical stress an Act of God damaged by accident tampered with or subjected to misuse or ab...

Page 66: ...66 111660 Rev C 5 13 14 Bennett 1218 E Pontaluna Road Spring Lake MI 49456 USA 800 235 7618 Outside USA 231 798 1310 sales bennettpump com www bennettpump com...

Reviews: