89000109-002
xVue Touch Installation Manual
Rev 2
Page 7-30
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
Figure 7-39 FlyQ Wi-Fi Connection Failed Message
If a power cycle occurs during database(s) download to the KSD 100EXP, all Seattle Avionics databases
will indicate “Database Load Fail” on the KSD 100EXP. To resolve the issue, try downloading again. The
program will try to continue to download from where the downloading process stopped.
7.5.2 xVue Touch Flight Software Update
The following system components of the xVue Touch System support update of software in the field
(provision for future SW upgrades):
• KSD 100EXP Primary Flight Display
The maintenance technician will check if the pre-loaded software in any of the xVue Touch System
components need an update. If any xVue Touch System components need a software update, the
maintenance technician will enter the Installer Menu and will select an option to update the KSD 100EXP
software.
The xVue Touch System components (Hardware and Software) have part numbers and serial numbers
stored in the various system component’s NVM. Installation of new software in a xVue Touch component
will change the part number of the unit and must follow the procedures defined for that specific software
update to ensure that the new software load is compatible with the existing hardware. The update must
be documented in a Service Bulletin or in an Installation Manual or other approved documentation that is
provided with the system update.
7.5.2.1 KSD 100EXP Software Update
When a software update is required for the KSD 100EXP the technician will download software onto a
USB drive and install into the front USB port on the KSD 100EXP. Prior to the software update, the
technician will be able to verify the USB software version. Once the software load begins, it may only be
canceled from the initial loading pop-up window. If the technician selects to continue the load, the KSD
100EXP will permanently update the application software.
If the software load is interrupted, the KSD 100EXP will provide a message regarding the data load failure
and the user will need to cycle power and repeat the loading process.
NOTE
DO NOT POWER OFF THE KSD 100EXP DURING THE SOFTWARE LOADING PROCESS UNTIL
PROMPTED TO CYCLE POWER THE UNIT.