![BENDIXKing KG 71EXP Installation Manual Download Page 71](http://html1.mh-extra.com/html/bendixking/kg-71exp/kg-71exp_installation-manual_2732185071.webp)
89000109-002
xVue Touch Installation Manual
Rev 2
Page 3-22
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft
technician. If the available area on the instrument panel allows, install the KCP 100EXP close to the KSD
100EXP. The KCP 100EXP may be located on any side of the KSD 100EXP based on user preference. The
KCP 100EXP dimensions allow for it to be installed in the radio stack as an alternative location. The KCP
100EXP can only be installed in the orientation that it was designed for (portrait or landscape).
3.6.7 KG 71EXP Installation Considerations
3.6.7.1 KG 71EXP Location
The KG 71EXP ADAHRS is recommended to be installed in an avionics bay area provided in the nose or tail
section of the airplane. The KG 71EXP must be mounted rigidly to the airplane structure. Do not use
shock mounting. Avoid areas prone to severe vibration (i.e. near engine mounts and landing gear) and
heat generating sources. Vibration outside of the DO-160G vibration level may result in degraded
accuracy. Verify the KG 71EXP is not the lowest point in the pitot/static system to reduce the chance of
allowing moisture to enter the unit.
The locations chosen for the KG 71EXP, and the method of installation, will vary with each specific type of
airplane. The unit should be installed in a convenient location for accessibility for inspection and
maintenance. The location should be close to the CG but not at the expense of a “hard to remove or test”
access point
.
Use the dimensions shown in Figure A-7
to prepare the mounting holes for the KG 71EXP (also refer to
the 1:1 scale drawing - available for download on the BendixKing Website - Dealer Portal).
NOTE
IF CROSS-COCKPIT OPERATION IS DESIRED, THE KCP 100EXP SHALL BE POSITIONED SO
THAT IT IS EASILY ACCESSED AND SEEN FROM BOTH PILOT POSITIONS.
NOTE
RECORD CROSS-COCKPIT CONFIGURATION STATUS IN THE AFP (REFER TO SECTION 4.13).
NOTE
THE KG 71EXP SETUP REQUIRES ACCESS TO THE MAINTENANCE PORT. WHEN INSTALLING
THE KG 71EXP IN A REMOTE LOCATION, ENSURE THAT THIS PORT IS ACCESSIBLE TO A
MAINTENANCE PC WHILE ENGINES ARE RUNNING.
NOTE
THE KG 71EXP IS NOT APPROVED FOR INSTALLATION INSIDE THE CABIN FOR AIRPLANES
WITH A STALL SPEED (V
SO
)GREATER THAN 64 KNOTS.
REFER TO SECTION 6.2.2.2 FOR AIRPLANE STALL SPEED (V
SO
) AND SETUP ON THE KSD.