6
Installation- Preparation
Continued ……………..
200817
Once the
2 x Screws
and
2 x Glass Brackets
are removed the
Glass
can be angled forward
(1)
from the top of the
fire and lifted out of the channel at the base of the glass.
(2) See diagram 4.
Note: Place the Glass, 2 x Glass Brackets and 2 x Screws in a safe place, as these will be required later.
Remove the
Cardboard Box
from inside the fire and depending on the model purchased, check the contents as
listed on
P4.
Note: Before proceeding further ensure there is power to the Fire (Suite), and it is operating correctly. (Follow
the separate fire operating instructions).
The next step is to decide on the installation location and before starting the installation ensure that there is
enough space to install the Suite -
See P3
, for the product overall sizes.
Note: If the suite is planned to be Floor-Standing
(with the plinth positioned below the suite) the Wall
Mount Bracket must be positioned 380mm from the
top of a level plinth to the top of the Wall Mount
Bracket. Follow P7-9
Note: Alternatively, if the suite is planned to be
positioned as a wall hung model (no plinth) the Wall
Mount Bracket may be positioned at any desired
height on the wall. However, consider the distance
from the bottom edge of the Suite to the top of the
Wall Mount Bracket is 512mm. Follow P10-14
For installation as a
Floor-Standing Suite
proceed to
P7.
For installation as a
Wall Mounted Suite
proceed to
P10
Diagram 4