[E611]
– [E612]
DISP [E611] - BAR [E612]
DISP [E611]
- Brightness (Background intensity) or display 0-100%.
Light time [E611 P]
is the illumination time that the display is lit after the last button press. The setting
can be from 0.1 second up to 60 seconds or “On", which gives constant illumination, which is also the
factory default.
Contrast [E611 PP]
Display blackness. Factory default is 80%. If the machine is placed high, the
entire display tends to turn black. Then lower the value. Alternatively, if placed low, increase the value
if the display blurred. During startup and when displaying
Reset menu
the display has a fixed value if
the user accidently sets a value hard to read.
Language [E611 PPP]
Ex can display text in two different languages. English and Norwegian.
BAR [E612]
Main screen can display up to two optional values.
Choosen parameter for upper bar
[E612]
will be shown on row 3, and
Chosen parameter for lower bar [E612 P]
on row 4.
Row 3 temporary displays the
DRAG
,
CATCH
and
BRAKE
if any of it’s buttons are pressed. Line 4
shows optional value all the time. Optional values are not showed simultaneously with
Line out,
if
Line out
font is selected to 100% (see
BIG [E613]
) because of the lack of space
The following options are available for upper and lower posts:
•
WEIGHT
. Motor power consumption. Each line corresponds to 0.4 amps and a block of 3 amps.
See
High load
or
Low load
on page Machine 4.
•
MotNm
(Newton meter). Shows how much torque the engine should provide. The value is
controlled automatically by Ex when increases / decreases
DRAG
.
•
Rpm
. Engine speed in revolutions per minute.
•
Batt
. Displays the battery voltage to Ex. Measured inside the machine at cable connections. May
be helpful to see if voltage drops occurred, caused by bad battery, defective joint, loop contact or if
long or straight cables are used.
•
Boos
t. Motor (internal) power supply voltage. Normally between 33-40 volt.
•
Temp
. The temperature inside the box.
•
ClutNm
(Newton meter). Shows how much torque the clutch should provide.
• -------. No value is displayed on the line.
Main screen
Navigate
[E6]
Screens
Min
Max
Factory
Step
Unit
Navigation
MORE
– DISP – DISP [E611]
DISPLAY
– Brightness
0
100
80
1
%
[E611]
DISPLAY
– Light time
OUT..60s.. IN
IN
0,1
Seconds
[E611 P]
DISPLAY
– Contrast
0
100
70
1
%
[E611 PP]
DISPLAY
– Language
Norwegian, Engelska
[E611 PPP]
MER- DISP - BAR [E612]
BAR - Choose upper parameter
See list above
[E612]
BAR
– Choose lower parameter
See list above
[E612 P]
Menu
[E61]
Table shows units and value limits. See
[E654]
for menu detail level setting. Some screens are not visible if simple view, or normal view are Chosen .