background image

HCP-1801HD/SD SDI Control Probe 

Guide to Installation and Operation 

M813-9900-111 

February 2013 

 

 

 

HCP-1801 

Page 1 of 24 

 

HCP-1801 

 

DESCRIPTION  

The HCP-1801 is a probe for the quality control of HD SDI 
(SMPTE 292 M) and SD SDI (SMPTE 259M-C) digital video 
signals. The HCP-1801 probe integrates several advanced 
features for monitoring both video and embedded audio 
signals. It offers complete real-time measurement and 
analysis of all relevant signal parameters as well as flexible 
alarm thresholds and user-defined profiles. In addition, the 
HCP-1801 probe functions as a distribution amplifier, with 
its HD/SD SDI input and four reclocked outputs. Used in 
conjunction with Miranda’s iControl family of products, the 
HCP-1801 allows users to see the signals they are 
monitoring. The probe generates real-time video thumbnails 
and audio level meters for transmission over IP networks. 
As part of the Miranda Densité series, the probe can be 
used along with a wide variety of interface and distribution 
amplifiers, and allows users to benefit from extensive 
flexibility and ease of use so unique to Miranda’s Densité 
platform. 

Input/output 

  Single input supports both SMPTE 259M-C digital video 

signal (SD) with embedded 272M digital audio, and 
SMPTE 292M digital video (HD) 

  Four outputs 

 

VBI signal extraction and analysis 

  24-bit digital audio disembedding 

 

Remote control and status 

  On card status Led 

  Current & latch status for remote reporting 

 

 
 

Monitoring of embedded audio 

  Signal presence detection and format validation 

  Presence control for each group 

  Adjustable level, phase and mono signal alarms 

  Selectable group, pair or individual channel monitoring 

 

Transmission over IP for display 

  Thumbnails with adjustable picture format, quality and 

transmission rate 

  Alarms and status 

  VITC, Closed captioning, V-chip, WSS and XDS 

  Audio level meters and phase meter 

  Audio overload counter 

  Video test pattern 

 

Video standard and presence monitoring  

  Video format detection

 

  Carrier detect

 

  Freeze detection (multi-zone)

 

  Black detection (multi-zone)

 

  Ancillary data detection and identification

 

  Luma min and max

 

  White max

 

  CC presence

 

  VITC presence

 

  VLI

 

 

WSS

 

 

Macro-block Detection (MBD) Option

 

 

 

FUNCTIONAL BLOCK DIAGRAM 

 

Thumbnail

Gen.

VBI

Extract

Video

Measure

Audio

Measure

Audio

Levels

HD/SD

SDI OUT

HD/SD

SDI IN

Micro-Controller

DATA OUT to ethernet interface in Densité frame

DEMUX

 

 

 

 

SPECIFICATIONS

 

 

 

VIDEO INPUT  

Signal: 

HD SDI: 

 

SD SDI: 

SMPTE 292M (1.485,1.485/1.001 Gbps) 
SMPTE 259M-C (270Mbps)  

Cable length:  HD 
 

SD 

110m. Belden 1694A at 1.485 Gbps 
250m. Belden 8281 at 270 Mbps 

Return loss: 

> 12 dB up to 1.5 GHz 

 

 

SERIAL DIGITAL OUTPUTS (4) 

Signal: 

SMPTE 292M (1.485,1.485/1.001 Gbps)   
SMPTE 259M (270 Mbps)  
(same format as input) 

Cable length:  HD 
 

SD 

110m. Belden 1694A at 1.485 Gbps 
250m. Belden 8281 at 270 Mbps 

Return loss: 

> 12 dB up to 1.5 GHz 

Added jitter 

<0.2UI p-p (wideband) 

Summary of Contents for Miranda DENSITE Series

Page 1: ...bit digital audio disembedding Remote control and status On card status Led Current latch status for remote reporting Monitoring of embedded audio Signal presence detection and format validation Pres...

Page 2: ...y and control panel are assigned to the card in the frame whose SELECT button has been pushed User Interface Pushing the SELECT button will cause the on card STATUS LED to flash yellow and the card id...

Page 3: ...MAX LEVEL MIN SILENCE DYNAMICS AUDIO PHASE STEREO WIDTH VERSION HCP 1801 xxx FACTORY DEFAULT RESTORE STATUS menu NO SIGNAL VIDEO 525 VIDEO 625 NO SIGNAL VIDEO 525 VIDEO 625 VIDEO 1080i 59 94 VIDEO 108...

Page 4: ...se Please consult the iControl User s Guide for information about setting up and operating iControl In iControl Navigator or iControl Websites double click on the HCP 1801 icon to open the control pan...

Page 5: ...which the HCP 1801 will detect a video freeze Black Zones a display of the areas within which the HCP 1801 will detect video black Info a listing of various information about the HCP 1801 card itself...

Page 6: ...ion of this panel Display Area Freeze Zones The display shows the current video thumbnail overlaid with boxes showing the four zones in which the HCP 1801 can detect a video freeze You can click on an...

Page 7: ...access this probe Remote System Administration Click on this button to open the Joining Locators HCP 1801 data entry box Display Area Macroblock The display shows a graph of the block artifact index...

Page 8: ...be used to return your probe to a standard operating condition To load it into the Current Profile right click on the Factory Profile icon then right or left click on the Load in Current text that app...

Page 9: ...x has a checkmark in it as shown in the example while an unselected box is blank Click on the box to change its status Because the HCP 1801 is concerned with detecting the presence of errors much of i...

Page 10: ...ders See page 9 for definitions of these parameters 525 White Max Check whether the luma content of the video signal is going higher than the specified threshold Enable check to enable this test Thres...

Page 11: ...hese four zones are common between the Freeze and Black parameters so they can be set up in either panel Enable check to enable this test Full Screen click this button to set the selected zone to full...

Page 12: ...m right corner Stop line pixel Note you can also set the zone size and position by clicking the Black tab in the display area and using your mouse to drag the outline of the zone Threshold set the lev...

Page 13: ...ll be extracted The available range is 11 12 13 19 20 525 AFD Detect the presence of Active Format Descriptor AFD data in the SDI video signal Enable check to enable this test Extract extract the AFD...

Page 14: ...and Interval Set up the error detection window using the sliders See page 9 for definitions of these variables 625 Luma Max Exp This measure verifies that the luma content of the video signal regular...

Page 15: ...each accessed from a tab Note these four zones are common between the Black and Freeze parameters so they can be set up in either panel Enable check to enable this test Full Screen click this button...

Page 16: ...value from the WSS and display it in the text box below Aspect Ratio The text box reports the detected aspect ratio 625 VITC Detect the presence of Vertical Interval Time Code VITC on a selected line...

Page 17: ...signal luma level will trigger an error message Duration Occurrence and Interval Set up the error detection window using the sliders See page 9 for definitions of these variables 1080i 720p Luma Min...

Page 18: ...ing monitored over the range Noisy to HiQ so that the Freeze algorithm will know how to treat noise when attempting to detect a frozen image Some experimentation may be required Duration Occurrence an...

Page 19: ...le check to enable this test Duration Set the time for which the CC must be continuously detected as invalid in order for this condition to be flagged 1080i 720p Close Caption Detect the presence of C...

Page 20: ...the presence of Dolby E encoded data in the SDI video signal Enable check to enable this test Extract extract the Dolby E program configuration and channel status and display them in this panel Line...

Page 21: ...ee page 9 for definitions of these variables Audio Overload Detect the highest level present in the signal both channels checked separately Enable Ch1 Enable Ch2 check to enable this test Threshold se...

Page 22: ...k to enable this test Threshold set the level in dB below which an Audio Dynamics error will be flagged Duration Occurrence and Interval Set up the error detection window using the sliders See page 9...

Page 23: ...flag to be generated detection window using the sliders See page 9 for definitions of these variables General AES Shows the contents of the AES channel status bits and the channel status data validit...

Page 24: ...ad Counters click this button to reset all the overload counters on the ALM display to zero See the next section for instructions on setting up the overload counters Meter Ballistics Config Type selec...

Page 25: ...ntains an expandable tree listing all the alarms reported by this HCP 1801 card Each alarm name includes an icon that shows its current status The Overall alarm and GSM contribution columns contain pu...

Page 26: ...ences Click in the checkbox to enable logging of alarm events for each individual alarm At the bottom of the window are several other controls Copy to other cards Click this button to open a panel tha...

Page 27: ...se This equipment has been tested and found to comply with the requirements of the EMC directive 2004 108 CE EN 55022 Class A radiated and conducted emissions EN 55024 Immunity of Information Technolo...

Reviews: