74
LAN_PORT_n_NAME
=
Ethernet port name as
defined by the OS
Typical example
format is:
FastEthernet0/24
Where FastEthernet is
the port type, other
reported types are
GigabitEthernet
0 is the interface
binding and 24 is the
physical port number
On devices with only
one physical 10/100
Ethernet connection
the reported string
would be:
FastEthernet0/1
LAN_PORT_n_SPEED
=
Ethernet connection
speed
10 Mbit/s Full Duplex
10 Mbit/s Half Duplex
100 Mbit/s Full
Duplex
100 Mbit/s Half
Duplex
1 Gbit/s Full Duplex
No Link
LAN speed in
megabits per second,
and duplex mode.
Use No Link when
Ethernet cable
unconnected or not
init.
LAN_PORT_n_LAST_
CHANGE=
Time from start since
last Port Change
Number
DDD:HH:MM:SS
Time change when IP
interface parameters
altered (ie IP subnet)
Uptime in specified
format updated every
minute, NOTE: field
value is zero buffered
001:08:10:00 (is 1 day,
8 hours, 10 minutes, 0
seconds)
Derived from MIB-II
ifLastChange
LAN_PORT_n_
ERRORS=
Total number errors
XXX in total
Summation of MIB-II
values
ifInDifInErrors
+ifInUnknownProtos
+ifOutDifOut
Errors.
Updated periodically
(60 sec interval)
LAN_PORT_n_
TRAFFIC_IN=
Traffic In/min
NNN.n Kbytes/sec
MIB-II ifInOctets. e.g.
“LAN_PORT_5_TRAFF
IC_IN=12.3 KBytes/
sec”
Format (“%0.1f”)
Field Name
Field Name
Description
Valid Field Values
Usage Description