48
Hardware Version
This displays the version number of the hardware used in the Gateway card.
Enclosure
This displays the IQ Modular enclosure type (IQH3B or IQH3BQ) that the Gateway is fitted to.
Software Version
This displays the software version installed.
Build Number
This displays the software build number of the unit.
Loader Version
This displays the version of the Gateway software loader. The loader operates at start-up only,
validating all Gateway files before the main application runs.
Java Applet Version
This shows the existence and the version of the Java Control Applet.
Menu Caches (Module)
The Gateway caches module menu sets locally to improve menu upload speeds. In rare
circumstances this may cause problems. If problems with module menu uploads are
encountered the menu caches can be cleared or caching disabled.
•
Format Now!:
This deletes the existing module menu caches. The caches will be recreated
when the next menu client connects.
•
Enable:
Select this box to enable the menu cache function.
Start Time
This displays the start time for the unit.
Misc Information 1/2
These information fields may be edited to specify any information desired. For example, these
could be used to add further information on the Gateway Card (rack position/building/ group).
2 fields are available allowing a maximum of 2 * 19 characters displayed. If these fields have
edited values then a corresponding log field gets raised.
Log field: INFORMATION1= and INFORMATION2=.
A global control for these logging fields applies in Logging(2).
Http Server
To enable increased security of control, either the http server may be disabled, to prevent
access to the Java Applet control panel or Homepage, or the port number for Http access may
be changed.
A check mark in the
Enable Web Svr
box will enable the web server control function. By
default, this option is enabled. Click to remove the check mark and disable this function. To
enter/modify the port number, type a new number in the editable field and click the Save (
S
)
button. To return to the default port number, click the Preset (
P
) button.
After changing the port number, you must restart the web server by disabling then enabling
the
Enable Web Svr
check box.