60
Slots (1-4), (5-8), (9-12), and (13-16)
The
Slots
pages allow each slot to be named and interrogated.
Name
The Name section displays the name and type of module fitted in the enclosure slot. See
Examples of Slot Use on page 63.
The following controls are provided:
•
Editable Name:
This enables a slot to be given a user name, e.g.
IQSYN22-ChanA
, and so
long as the correct card stays in that slot this name will be used, as defined by matching
Installed Unit ID and Bound Type ID.
However, if the card is replaced with an incorrect type, e.g. a serial interface, the card will
appear by its type generic name e.g. IQCSPI. Although the values in this edit box remains
the same. When this entry is edited, the current Installed Unit ID gets copied to the Bound
Type ID.
To enter/modify the unit name, type a new name in the editable field and click the Save (
S
)
button. To return to the default name, click the Preset (
P
) button.
•
Fitted Unit Type:
This shows the type of the module fitted in the slot, e.g.
IQSYN22
. If no
module is in the slot,
No Unit Fitted
is displayed. If an incompatible module is fitted into a
slot,
NOT RollCall 3!
is displayed.
Editable Name
Installed Unit Type
Preset
Save
Summary of Contents for grass valley IQH3B Series