Assembly and wiring
Technical manual LioN-Link BusHead EtherNet/IP™
Release 1.1 04/2016
4.4 Port assignments
21
Figure 5: Port assignment EtherNet
4.4.6
Functional ground
Information on the reference earth is provided in the assembly instructions
(see
“General information” on page 15
4.4.7
Intermediate voltage feed
When planning a machine or system, note that intermediate feeding of the
supply voltage may be necessary for the I/O modules' electronics and sensor
system.
If the power supply is not sufficient, the I/O modules output a diagnostic
message. The warning limit for diagnostics is at approx. 19 V DC.
Pin
Signal
Function
1
TD +
Transmit data plus
2
RD +
Receive data plus
3
TD -
Transmit data minus
4
RD -
Receive data minus
Table 6:
Port assignment EtherNet
NOTE
All M12 metal sleeves are electrically connection via functional ground.