background image

Technical manual  LioN-P/ -R EtherNet/IP

Release 1.4 02/2016

Technical support

[email protected]

Technical manual

LioN-P EtherNet/IP with QuickConnect
0980 ESL 311-xxx ... 0980 ESL 313-xxx
0980 ESL 391-xxx ... 0980 ESL 393-xxx

LioN-R EtherNet/IP with QuickConnect
0980 ESL 811-EIP 16DI-M12-R
0980 ESL 812-EIP 16DO-M12-R
0980 ESL 813-EIP 8DI/8DO-M12-R

Summary of Contents for 934 691-001

Page 1: ...support automation belden com Technical manual LioN P EtherNet IP with QuickConnect 0980 ESL 311 xxx 0980 ESL 313 xxx 0980 ESL 391 xxx 0980 ESL 393 xxx LioN R EtherNet IP with QuickConnect 0980 ESL 81...

Page 2: ...2 Technical manual LioN P R EtherNet IP Release 1 4 02 2016...

Page 3: ...ial product features 13 3 3 Product overview 14 4 Assembly and wiring 17 4 1 General information 17 4 2 Outer dimensions 19 4 2 1 Module 0980 ESL 813 EIP 8DI 8DO M12 R 19 4 2 2 Module 0980 ESL 313 111...

Page 4: ...45 7 1 How it works 45 7 2 Activation 45 7 2 1 Configuration assembly instance 105 46 7 2 2 EtherNet IP object TCP IP object 46 8 Bit assignment 49 8 1 16DI module 49 8 1 1 Assembly instance ID 101 in...

Page 5: ...54 9 3 Overload of output drivers 54 9 4 Error in the actuator power supply 55 9 5 Error in the system sensor power supply 55 10 Technical data 57 10 1 General 57 10 2 Bus system 57 10 3 Power supply...

Page 6: ...Content 6 Technical manual LioN P R EtherNet IP Release 1 4 02 2016...

Page 7: ...used in this manual are used exclusively to explain how to operate and apply the LioN P and LioN R P modules with EtherNet IP interface Please contact us if you have any detailed questions on install...

Page 8: ...or substantial damage to property will occur if the required safety measures are not taken WARNING Means that death serious physical injury or substantial damage to property can occur if the required...

Page 9: ...information Index Created Changed Changed Version number Version 1 0 Version 1 1 Version 1 2 Date March 2013 May 2013 Aug 2014 Name department Knipp PM Knipp PM Knipp PM Version number Version 1 3 Ve...

Page 10: ...About this manual 10 1 3 Version information Technical manual LioN P R EtherNet IP Release 1 4 02 2016...

Page 11: ...d in the industrial sector The industrial environment is distinguished by the fact that the consumer is not connected directly to the public low voltage network Additional measures are required for us...

Page 12: ...are based on the requirement profiles described by ZVEI VDMA or equivalent organizations Only electricians who are familiar with the content of this manual are authorized to install and maintain the...

Page 13: ...dule electronics from environmental effects and allows the device to be used in a wide temperature range Despite the sturdy construction the modules have compact dimensions and a low weight They are e...

Page 14: ...e the behavior of every single output channel in the case of an interruption or a loss of communication Integrated web server The network parameters such as IP address subnet mask and gateway can be a...

Page 15: ...0980 ESL 812 EIP 16DO M12 R SAP number 934 691 002 0980 ESL 312 111 single protocol SAP number 934 880 002 0980 ESL 312 121 single protocol SAP number 934 839 002 0980 ESL 392 111 multiprotocol SAP nu...

Page 16: ...System description 16 3 3 Product overview Technical manual LioN P R EtherNet IP Release 1 4 02 2016...

Page 17: ...ocket and a distance of 196 8 to 198 3 mm for LioN P modules with M12 power L coded Note The modules have a ground connection with an M4 thread for the conduction of interference currents and the EMC...

Page 18: ...ries Note For UL application Only approved for interior use Please note the maximum elevation of 2000 meters Approved up to a maximum soiling level of 2 WARNING Terminals housings field wired terminal...

Page 19: ...Assembly and wiring Technical manual LioN P R EtherNet IP Release 1 4 02 2016 4 2 Outer dimensions 19 4 2 Outer dimensions 4 2 1 Module 0980 ESL 813 EIP 8DI 8DO M12 R...

Page 20: ...Assembly and wiring 20 4 2 Outer dimensions Technical manual LioN P R EtherNet IP Release 1 4 02 2016 4 2 2 Module 0980 ESL 313 111...

Page 21: ...Assembly and wiring Technical manual LioN P R EtherNet IP Release 1 4 02 2016 4 2 Outer dimensions 21 4 2 3 Module 0980 ESL 313 121...

Page 22: ...1 Ethernet IP ports Design M12 socket 4 pin D coded Color coding green Figure 1 Schematic drawing ports X01 X02 4 3 2 Ports for the power supply Design MINI 7 8 connector socket 4 pin Color coding gr...

Page 23: ...ensors US 3 0 V DC System sensors US 4 0 V DC Actuator UL Table 4 Assignment of ports X03 X04 NOTE Only use power supply units for the system sensor and actuator supply that correspond to PELV Protect...

Page 24: ...1 0980 ESL 802 0980 ESL 803 Power supply X03 X04 1 see note Actuator GND 0V 2 GND 0V System sensors GND 0V 3 FE Ground Functional ground 4 24 V System sensors US 24 V 5 see note Actuator VL 24 V Table...

Page 25: ...supply units for the system sensor and actuator supply that correspond to PELV Protective Extra Low Voltage or SELV Safety Extra Low Voltage Power supplies according to EN 61558 2 6 transformers or EN...

Page 26: ...Protective Extra Low Voltage or SELV Safety Extra Low Voltage Power supplies according to EN 61558 2 6 transformers or EN 60950 1 switching power supply units fulfill these requirements Port Pin Funct...

Page 27: ...unpack it The archive contains the following EDS files EDS V3 9 LumbergAutomation 0980ESL811 yyyymmdd eds EDS V3 9 LumbergAutomation 0980ESL812 yyyymmdd eds EDS V3 9 LumbergAutomation 0980ESL813 yyyy...

Page 28: ...tings The devices support the DHCP and BOOTP protocols for receiving the required network parameters such as IP address and subnet mask The factory settings of the static network parameters are IP add...

Page 29: ...used Rotary switch setting Function 000 state on delivery In the state on delivery the DHCP and BOOTP functions are activated The network parameters are initially requested via DHCP requests If this i...

Page 30: ...Connection type Diagnostics Instance ID Length Input Only Yes Output 193 0 byte Input 101 4 byte Input Only No Output 193 0 byte Input 102 3 byte Listen Only Yes Output 192 0 byte Input 101 4 byte Lis...

Page 31: ...el Listen Only Yes Output 192 0 byte Input 101 7 byte Listen Only No Output 192 0 byte Input 102 3 byte Connection type Diagnostics Instance ID Length Exclusive Owner Yes Output 100 1 byte Input 101 6...

Page 32: ...of the surveillance timeout is 0 to 255 ms The standard value is 80 ms When the output channel is in the static state i e the channel is permanently switched on or off the value is 100 ms MSB LSB 15 1...

Page 33: ...ng a control system from another provider please consider the related documentation Install the EDS files of the modules in RSLogix5000 with the EDS hardware installation tool under the Tools menu Sel...

Page 34: ...anual LioN P R EtherNet IP Release 1 4 02 2016 Go to the I O Configuration section in the Controller Organizer and right click on Ethernet Select the New Module menu item The following selection windo...

Page 35: ...ick the Change button and change the setting for the module revision electronic keying and connection type Select the connection type This specifies which process and diagnostic data the module provid...

Page 36: ...1 4 02 2016 Change to the Controller Tags section in Controller Organizer The controller tags for the configuration parameters contain the name of the module followed by a C The surveillance timeout a...

Page 37: ...mum 2 ms LioN P Sender to target device O T connection parameters Real time transfer format Heartbeat Connection type POINT2POINT Assembly instance ID 193 Data type USINT Data size 1 byte Data length...

Page 38: ...ort type Exclusive Owner Trigger mode Cyclic Requested packet interval RPI Minimum 5 ms LioN R Minimum 2 ms LioN P Sender to target device O T connection parameters Real time transfer format 32 bit ru...

Page 39: ...e the option to call up the websites saved on it by entering the address in a web browser To do this replace the placeholder IP Adresse with the IP address of the relevant module 6 1 The Home page The...

Page 40: ...and writable Gateway address readable and writable Start configuration Fix The module uses the IP settings defined by the above parameters BOOTP The module receives the IP settings via a BOOTP server...

Page 41: ...ta Consumed Input data Produced with diagnosis Status of the LAN ports Duplex mode full duplex half duplex Transmission rate 10 MBit 100 MBit Network address MAC address Size and data direction of the...

Page 42: ...e Contact page Technical manual LioN P R EtherNet IP Release 1 4 02 2016 6 4 The Contact page The address of the contact page is http IP Adresse contact htm This page provides information on the conta...

Page 43: ...erver The web server provides the data in standardized JSON format The data is accessed via the website The relevant address is http IP Adresse data jsn In higher programming languages the process and...

Page 44: ...diagno stic data Technical manual LioN P R EtherNet IP Release 1 4 02 2016 The response has the following object structure Consumed Array a b contains the output data of the module Produced Array a b...

Page 45: ...nd DHCP BOOTP are not supported Please note that no automatic check is performed for IP addresses that are assigned more than once in the same network When QuickConnect is activated the following para...

Page 46: ...r Organizer select the Controller Tags section and set the QuickConnectEn bit to the value 1 7 2 2 EtherNet IP object TCP IP object Enter a message command from the command list and open the related c...

Page 47: ...QuickConnect Technical manual LioN P R EtherNet IP Release 1 4 02 2016 7 2 Activation 47...

Page 48: ...QuickConnect 48 7 2 Activation Technical manual LioN P R EtherNet IP Release 1 4 02 2016...

Page 49: ...ata without diagnosis 8 1 3 Key X1 A X8 A Input status channel A contact pin 4 of slots X1 to X8 X1 B X8 B Input status channel B contact pin 2 of slots X1 to X8 MI LVS Module information byte undervo...

Page 50: ...3 Bit 2 Bit 1 Bit 0 Byte 0 X4 B X4 A X3 B X3 A X2 B X2 A X1 B X1 A Byte 1 X8 B X8 A X7 B X7 A X6 B X6 A X5 B X5 A Byte 2 MI IME 0 0 0 MI SCA 0 MI LVA MI LVS Byte 3 0 0 0 0 0 0 0 0 Byte 4 0 0 0 0 0 0 0...

Page 51: ...NPUT Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 X4 B X4 A X3 B X3 A X2 B X2 A X1 B X1 A Byte 1 X8 B X8 A X7 B X7 A X6 B X6 A X5 B X5 A Byte 2 MI IME 0 0 0 MI SCA MI SCS MI LVA MI LVS Byte...

Page 52: ...s channel B contact pin 2 of slots X5 to X8 MI LVS Module information byte undervoltage for system sensor power supply MI LVA Module information byte actuator undervoltage MI SCS Module information by...

Page 53: ...of the module The value of this parameter can range from 0 to 255 ms the factory setting is 80 ms Target value Actual value Comment Active Active OK no diagnosis Off Off OK no diagnosis Active Off Sho...

Page 54: ...et light up red and the relevant error bit for the sensor short circuit is set in the diagnosis bytes The error message is filtered by the Surveillance Timeout parameter 9 3 Overload of output drivers...

Page 55: ...The error message is filtered by means of a fixed filter period of 300 ms 9 5 Error in the system sensor power supply The voltage value for the system sensor power supply is also monitored globally If...

Page 56: ...therNet IP Release 1 4 02 2016 The error message has no effect on the outputs and is not filtered but is reported immediately Caution It must definitely be ensured that the supply voltage measured at...

Page 57: ...s Torques M6 fixing screws M4 ground connection M12 connector 1 0 Nm 1 0 Nm 0 5 Nm Table 29 General information Protocol EtherNet IP EDS files EDS V3 9 LumbergAutomation 0980ESL811 yyyymmdd eds EDS V3...

Page 58: ...I 7 8P MP 39200 0980 ESL 392 111 16DO 7 8P MP 39300 0980 ESL 393 111 8DI8DO 7 8P MP 39102 0980 ESL 391 121 16DI M12P MP 39202 0980 ESL 392 121 16DO M12P MP 39302 0980 ESL 393 121 8DI8DO M12P MP Suppor...

Page 59: ...larity protection Yes Operational indicator UL LED green 18 V UL 30 V LED red UL 18 V or UL 30 V Table 32 Information on the power supply for the actuators Input connection Type 3 as per IEC 61131 2 N...

Page 60: ...ls 0 with 16 DI 16 with 16DO 8 with 8DI 8DO Channel type Normally open p switching Status indicator LED yellow per channel A LED white per channel B Diagnosis indicator LED red per channel Port M12 so...

Page 61: ...ubscriber No link no data exchange MS Green Device ready for operation Flashing green Device ready but not configured Red Serious error that cannot be resolved Flashing red Minor error that can be res...

Page 62: ...Technical data 62 10 7 LEDs Technical manual LioN P R EtherNet IP Release 1 4 02 2016...

Page 63: ...Declaration of conformity Technical manual LioN P R EtherNet IP Release 1 4 02 2016 63 11 Declaration of conformity...

Page 64: ...Declaration of conformity 64 Technical manual LioN P R EtherNet IP Release 1 4 02 2016...

Page 65: ...ector at both ends straight 4 pin D coded and RJ45 connector 26AWG PUR halogen free with water blue casing multi wire shielded 2 twisted wire pairs 0985 706 100 M Connection cable for PROFINET with M1...

Page 66: ...cable plug RS and socket RK straight 4 pin 18AWG TPE conductor IEC color coded RSRK 40 602 M MINI 7 8 connection cable both ends with cable plug RS and socket RK straight 4 pin 18AWG PUR conductor IEC...

Page 67: ...ories Technical manual LioN P R EtherNet IP Release 1 4 02 2016 67 Item number Description RKV Cover for unused MINI 7 8 device sockets RSV Cover for unused MINI 7 8 device plugs Table 40 Other access...

Page 68: ...Accessories 68 Technical manual LioN P R EtherNet IP Release 1 4 02 2016...

Reviews: