SUDZAMELEON
®
ARCH
1MANUL956
Belanger®, Inc. *PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
47
Utilities
Connecting MixStir® to the Sudzameleon® Arch
Connecting MixStir® to Leg Assembly Manifolds
1)
Replace the ¼” elbow fitting on the Regulator of the MixStir® with the supplied ½” elbow fitting.
2) Run the Compressed Airline Feed from
the Pneumatic Regulator on the MixStir® out to
the Utility Plate on the Sudzameleon®.
3) Run the Chemical Solution Airline Feed from
the Pump on the MixStir® out to the Utility
Plate.
4) Turn on the MixStir® to verify that the chemical
is getting out to the bay and to flush out any
unwanted debris that may be in the line.
5) The MixStir® will be connected to the Leg
Assembly Manifolds through the fittings on the
Utility Plate on the Air Plenum.
6) Connect the Chemical Solution Feedline to the
top left fitting on the Utility Plate Fitting and
connect the Compressed Air Line to the top
right fitting on the Utility Plate, refer to the
image below.
7) Turn on the MixStir®, make sure that the solution is spraying out of all six Nozzles properly.
Chemical Solution
Main Feed Line
Pump
Compressed Air
Main Feed Line
MixStir® Air Pump Panel
Supplied ½” Elbow
Fitting to replace
current fitting
Pneumatic
Regulator
Connect Line for
Chemical Solution
Connect Line for
Compressed Air
Utility Plate
Panel for
Bayonet Nozzles
Panel for
Leg Manifolds
Top Fittings to feed
Leg Manifolds
Chemical Solution
Compressed Air