![Belanger Signature Series Owner'S Manual Download Page 63](http://html.mh-extra.com/html/belanger/signature-series/signature-series_owners-manual_2725312063.webp)
INTEGRA® / E-1063
1MANUL102
Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681
5-17
Chapter 5 Operator Interface/Wash Setup Screens
Setup
SETUP / MISC
There are 2 MISC screens. Both are covered below and on the following page.
Misc (first screen)
Pressing the MISC key will take you to the following screen.
When you are done with this screen, press the MORE key to move to the second screen associated with MISC.
•
Conveyor / Equipment Hydraulic Power Up Delay: Displays the seconds required for the Main Hydraulic
Unit to turn back ON after an E-Stop or Power Up condition. The actual time will be 2.5 seconds longer due
to time required for the horn to sound. Equipment that has a Power-Up delay is: Conveyor, Named 1, Named
5, Named 19, Equipment Hydraulics, and Dryer Group 2.
•
Equipment Hydraulic Power Up Delay: This function delays in seconds the activation of the second
Hydraulic Unit after an E-Stop or Power Up condition. The actual time will be 2.5 seconds longer due to time
required for horn to sound.
•
Conveyor Length: Displays the Conveyor length in inches. This function should be set at a minimum of 1
inch past the last functions ON point. This is NOT the actual Conveyor length; it is a value greater than the
distance from the Photo Eye to the final component in the system.
•
Example: Set it to 1 inch past the ON position of the exit Dryers.
•
Conveyor Off Delay: This shows the amount of seconds the Conveyor / Main Hydraulic Unit will remain ON
after the last vehicle is no longer signaling the Conveyor to run. Increase Delay if Rear Tire Dollies are
remaining on the Conveyor.
•
Power Up Choice: This function toggles back and forth between “Enabled” and Disabled”. When Enabled,
the operator will have to “ACCEPT” the current status of the wash after a Power-up before wash will
continue. ACCEPT on the Power-up screen is not the same as the Stand-By ACCEPT.
•
Conveyor Pulse Distance: You MUST specify the Conveyor pulse distance. The system uses this
measurement to calculate one inch of travel (this is the distance the chain travels from the edge of one
Conveyor Proximity Input to the next).
NOTE: Image above shows Pulse setting for the DuraTrans DXD Conveyor at 8.26. The setting for
DuraTrans CLASSIC should be 7.85
Summary of Contents for Signature Series
Page 2: ......
Page 4: ......
Page 7: ...Chapter 1 Introduction Chapter 1 Introduction Chapter REV 01 ...
Page 8: ......
Page 13: ...Chapter 2 General Machine Operations Chapter 2 System Overview Chapter REV 01 ...
Page 14: ......
Page 22: ......
Page 24: ......
Page 28: ......
Page 46: ......
Page 69: ...Chapter 6 Techniques in Programming Chapter 6 Techniques in Wash Setup Chapter REV 01 ...
Page 70: ......
Page 76: ......
Page 77: ...Chapter 7 Faults and Alarms Chapter 7 Faults and Alarms Chapter REV 01 ...
Page 78: ......
Page 86: ......
Page 91: ...Chapter 9 E 1063 Screen Map Chapter 9 E 1063 Programming Screen Map Chapter REV 01 ...
Page 92: ......
Page 93: ......