Assembly work
Illustration
Description / explanation
17
22
21
C
D
17
D
10
F
F
10
Horizontal connection of the condensate inlet line
1. Remove the plugs
[17, 10]
on the condensate inlet
[D]
and condensate discharge
[F]
.
Vertical connection of the condensate inlet line
1. Remove the plugs
[17, 10]
on the condensate inlet
[D]
and condensate discharge
[F]
. Screw the locking
screw
[22]
with the flat gasket
[21]
out.
21
D
22
9
F
9
F
Horizontal connection of the condensate inlet line
2. Screw the hose connection provided
[9]
to the
condensate discharge
[F]
and tighten with a torque of
3 … 4 Nm (2.21 … 2.95 ft-lb).
Vertical connection of the condensate inlet line
2. Screw the hose connection provided
[9]
to the
condensate discharge
[F]
and tighten with a torque of
3 … 4 Nm (2.21 … 2.95 ft-lb).
Screw the locking screw
[22]
with the flat gasket
[21]
into the condensate inlet
[D]
and tighten firmly with a
torque of 35 Nm +2 Nm (25.82 ft-lb +1.46 ft-lb).
BEKOMAT
®
33iU / 33iU CO
Original installation and operation manual
32 | 68