Exchange work
Illustration
Description / explanation
9
X3
34. Fit the hose connection
[9]
with the hose
[X3]
.
X2
X1
35.
Carry out a leakage test on all screw fittings.
36. Carefully open the condensate feed via the condensate
inlet lines
[X1]
(e.g. by opening the recommended
shut-off valve
[X2]
).
10.3.2 Functional test
Illustration
Description / explanation
Power
Alarm
Service
TEST
Press the TEST button for 2 … 5 seconds.
0
The red ALARM LED is off
0
The green POWER LED is illuminated (100 %
brightness)
0
The valve opens and condensate is drained
Original installation and operation manual
BEKOMAT
®
33iU / 33iU CO
53 | 68