9.3.4 Alarm enable:
EnbL
This function allows the alarm to be enabled or
disabled without altering any of the alarm parameters.
Using the
&
or
*
push button select
AL1
or
AL2
from the configuration menu and press
(
to access
the alarm sub-menu. Press the
&
or
*
button until
EnbL
is displayed followed by
(
which will reveal if
the function is
on
or
off.
The setting can be changed
by pressing the
&
or
*
push button followed by the
)
button to return to the alarm sub-menu.
9.3.5 Type of alarm:
tYPE
Alarm 1 and Alarm 2 are totally independent, both
may be speed or run-time alarms, or one may be
conditioned for speed and the other for run-time.
Using the
&
or
*
push button select
tYPE
from the
selected alarm sub-menu and press
(
to check or
change the function. The
&
or
*
push button will
toggle the selection between
5PEEd
and
Hour5
, when
set as required press the
)
button to return to the
alarm sub-menu.
Note:
When
tYPE
is changed, the alarm
configuration is automatically reset to the
default values and the alarm is disabled. It
must therefore be reconfigured before use.