6.16  Local grand total run-time reset:  

clr gtot

The  grand  total  run-time  is  a  separate  timer  that
functions in parallel with the run-time display, but is
not zeroed when the run-time display is reset to zero.
The run-time grand total may be viewed in the display
mode  by  pressing  the  

)

 and  

*

 buttons

simultaneously.

Clr gtot

  is  a  sub-menu  in  the  

LoC clr

 function

which when activated allows an operator to reset the
grand total run-time to zero while the Tachometer is in
the display mode by operating the  

)

 and  

*

 push

buttons  simultaneously  for  more  than  ten  seconds.
See section 2.2

To check or change the function select 

LoC clr

 in the

configuration menu and press 

which will reveal the

clr tot  

prompt.  Using the  

&

 or  

*

 button select

clr gtot

 and press  

(

 which will show

 

if the local

grand  total  reset  is  

on

 or  

oFF

.      If  set  as  required

operate  the  

)  

button  twice  to  return  to  the

configuration menu, or the 

&

 or 

*

 button to change

the setting followed by the  

)

 button twice to enter

the change and return to the  

LoC clr

 prompt in the

configuration menu.

Note:

 

Once reset, the grand total run-time can not be
recovered.

6.17  Grand total run-time reset from within
         the configuration menu:  

Clr

   

Gtot

The  grand total  run-time is a separate  timer that is
incremented in parallel with the run-time display, but is
not zeroed when the run-time display is reset to zero.
The grand total may be viewed in the display mode by
pressing the 

)

 and 

*

 buttons simultaneously.

The grand total can be reset to zero from within the
configuration menu using this 

Clr 

 

Gtot

 function.

To zero the grand total from within the configuration
menu select 

Clr 

 

Gtot

 and press 

(

 which will cause

the  instrument  to  display  

Clr

 

.

 

no

 with  

no

 flashing.

Press  the  

&

 or  

*

 push  button  until  

Clr

 

.

 

YE5

 is

displayed  and  then  press  

(

  which  will  result  in  a

0000

  prompt  being  displayed  with  the  first  digit

flashing.  This is a request for the instruction to be
confirmed by entering 

5urE

 using the 

&

 or 

*

 

button

to adjust the flashing digit and the 

(

 button to move

control to the next digit.  Pressing  

)

 will then reset

the grand total to zero and return the Tachometer to
the  configuration menu.

Note:

Once reset, the grand total run-time can not be
recovered.

6.18  Security code:  

CodE

Access to the instrument’s configuration menu may
be protected by a four digit security code which must
be entered to gain access.   New instruments are
configured with the default security code 

0000

 which

allows  unrestricted  access  to  all  configuration
functions.

To enter a new security code select  

CodE

 from the

configuration menu and press  

(

 which will cause

the  Tachometer  to  display  

0000

 with  one  digit

flashing.  The flashing digit may be adjusted using
the  

&

 or  

*

  push  button  and  the  

(  

button  to

transfer control to the next digit.   When all the digits
have been adjusted press  

)

 to return to the  

CodE

prompt. The revised security code will be activated
when  the  Tachometer  is  returned  to  the  display
mode.

Please contact BEKA associates sales department if
the security code is lost.

6.19  Reset configuration to factory defaults:

r5Et  Def

r5Et

 

Def 

resets the Tachometer configuration to the

factory default configurations shown in sections 6.0.

To  reset  the  Tachometer  to  the  factory  default
configurations select 

r5Et def 

from the configuration

menu  and  press  

(

 

which  will

 

result  in  the

instrument  displaying  

0000

  with  the  first  digit

flashing.  To confirm the instruction  

5urE

 should be

entered.   Using  the  

&

 or  

*

  button  set the  first

flashing digit to  

5

 and press  

(  

which will transfer

control to the second digit which should be set to 

u

.

When  

5urE

  has  been  entered  pressing  the  

)

button will reset all the configuration functions and
return the instrument to the display mode.

21

Summary of Contents for BA314NG

Page 1: ...Issue 5 9th July 2019 BA314NG Ex nA and Ex tc Tachometer Issue 5...

Page 2: ...dAtE 6 8 Run time display di5P 2 6 9 Position of the decimal points dP 6 10 Speed scale factor 5CALE 5 6 11 Timebase t bA5E 6 12 Display filter FiLtEr 6 13 Clip off CLP oFF 6 14 Local reset LoC clr 6...

Page 3: ...larm silence time 5IL 9 3 12 Flash display when alarm occurs FL5H 9 3 13 Access Setpoint AC5P 9 3 14 Adjusting alarm setpoints from the display mode 9 4 4 20mA output 9 4 1 Ex nA certification 9 4 2 S...

Page 4: ...m compliance with the European ATEX Directive 2014 34 EU For international applications the BA314NG also has IECEx certification which is described in Appendix 2 For applications in the USA and Canada...

Page 5: ...the Tachometer may be configured to provide direct access to the alarm setpoints from the display mode when the and buttons are operated simultaneously See 9 3 13 and 9 3 14 2 3 Displays The BA314NG...

Page 6: ...the Type Examination Certificate This allows the Tachometer to be adjusted and configured live when installed in Zones 2 When connected to a suitable system the BA314NG Tachometer may be installed in...

Page 7: ...ety parameters Input Output Type of input Link 3 4 Ui Uo Io Switch contact Yes 15V 10 5V 9 2mA Proximity detector Yes 15V 10 5V 9 2mA Open collector Yes 15V 10 5V 9 2mA Magnetic pick off No 30V 1 1V 0...

Page 8: ...that terminals 2 6 and RS2 are interconnected within the BA314NG See Fig 1 4 1 Power supply The BA314NG Tachometer requires a minimum of 10V between terminal 1 2 and consumes 10mA without optional bac...

Page 9: ...eshold and rise above the upper thresholds shown in the following table Input transducer Switching thresholds Lower Upper Open collector 2k 10k Voltage pulse low 1 0V 3 0V Voltage pulse high 3 0V 10 0...

Page 10: ...d associated wiring should be able to withstand a 500V rms insulation test to earth The BA314NG contains a configurable debounce circuit to prevent false triggering See section 6 6 4 2 6 Voltage pulse...

Page 11: ...the bottom right hand corner the back box for interconnecting cable screens The BA314NG Tachometer may be pipe mounted using a BA393G pipe mounting kit 5 2 Installation Procedure Fig 6 illustrates the...

Page 12: ...instrument is ordered a blank scale card will be fitted which can easily be marked on site with a dry transfer or a permanent marker Custom printed scale cards are available from BEKA associates as a...

Page 13: ...factor that determines whether the Tachometer displays speed per second per minute or per hour The Tachometer incorporates a run time counter that displays the time in hours that the speed of the mon...

Page 14: ...on or oFF See section 6 8 Display Summary of function dP Decimal points Defines the position of the decimal point in the Tachometer speed display See section 6 9 5CALE 5 Speed scale factor 5CALE 5 is...

Page 15: ...6 Display Summary of function CLr Gtot Resets grand total run time to zero This function resets the grand total run time to zero from within the configuration menu when CLr YE5 is selected and 5urE is...

Page 16: ...16...

Page 17: ...17...

Page 18: ...ges such as those resulting from a mechanical contact closing and bouncing Three levels of protection may be selected and the amount of debounce applied depends upon the type of Tachometer input that...

Page 19: ...g shaft generates 18 pulses per revolution to produce a Tachometer speed display in revolutions 5CALE 5 should be set to 18 0 The units of the Tachometer speed display are pulses per unit of time The...

Page 20: ...sed it is not necessary to enter a clip off value see 6 8 To check or change the clip off threshold select CLP oFF from the configuration menu and press which will reveal the current setting The thres...

Page 21: ...isplayed and then press which will result in a 0000 prompt being displayed with the first digit flashing This is a request for the instruction to be confirmed by entering 5urE using the or button to a...

Page 22: ...the wires entering the hazardous area should be individually fused and contain a means of isolation These two requirements may be satisfied by installing DIN rail mounted terminals incorporating a fus...

Page 23: ...ting on or oFF The function can be changed by pressing the or push button followed by the button to return to EnbL prompt in the sub menu 6 20 6 Source of output pulse 5ourCE The output pulse may be d...

Page 24: ...to select the required value followed by the button to return to durAtion prompt in the sub menu Note This function only appears in the pulse output sub menu when 5CALEd is selected in the 5ource sub...

Page 25: ...al between display updates Using the or button select uPdAtE in the configuration menu and press to reveal how frequently the Tachometer display is updated Using the or push button select 0 5 0 5 seco...

Page 26: ...h buttons The button will transfer control to the second digit which controls the step response and should be set to 0 in the same way Finally enter the selection and return to the FiLtEr prompt in th...

Page 27: ...s unauthorised access to the configuration menu Using the or button select CodE from the configuration menu and press which will reveal 0000 with the first digit flashing This example requires the sec...

Page 28: ...ion change Re enable both alarms See 9 3 4 8 2 Fault finding after commissioning EN 60079 17 Electrical installations inspection and maintenance permits live maintenance in Zone 2 if a risk analysis d...

Page 29: ...your local BEKA agent It is helpful if a brief description of the fault symptoms is provided 8 6 Customer comments BEKA associates is always pleased to receive comments from customers about our produ...

Page 30: ...with factory fitted dual isolated solid state single pole alarm outputs that may be independently configured Each may be configured as a speed or run time alarm with a high or low function having a no...

Page 31: ...the means of isolation is essential for their effective use It is also necessary to ensure that the maintenance procedure makes sure that unauthorised re closure of the switches does not occur It is n...

Page 32: ...t and the alarm output being activated See section 9 3 10 5IL Alarm silence time Defines the time that the alarm output remains in the non alarm condition following acceptance of an alarm See section...

Page 33: ...to return to the alarm sub menu 9 3 5 Type of alarm tYPE Alarm 1 and Alarm 2 are totally independent both may be speed or run time alarms or one may be conditioned for speed and the other for run time...

Page 34: ...ggle the contact status between no and nC when set as required press the button to return to the no nC prompt in the alarm sub menu 9 3 9 Hysteresis H5tr Hysteresis is only available on speed alarms s...

Page 35: ...l adjustment is provided by a separate security access code Using the or push button select AC5P from the configuration menu and press to reach the enable function EnbL Pressing will reveal the existi...

Page 36: ...the or push button and the button to transfer control to the next digit When the required setpoint has been entered pressing will return the display to the 5P1x or 5P2x prompt from which the other se...

Page 37: ...ed and contain a means of isolation These two requirements may be satisfied by installing DIN rail mounted terminals incorporating a fuse which can easily be opened as shown in Fig 2 to provide isolat...

Page 38: ...g the or push button select 4 000 in the 4 20mA output sub menu and press to reveal the existing speed display with one digit flashing The required display can be entered using the or push button to a...

Page 39: ...cate indicated by the certificate number s X suffix These state that the BA314NG Tachometer should be a Supplied from a limited energy circuit with output parameters in normal operation equal to or le...

Page 40: ...ical to the ATEX safety parameters described in the main section and in Appendix 1 of this manual The IECEx certificate may be downloaded from the BEKA associates or the IECEx website or may be reques...

Page 41: ...T5 Gc Zone 22 AEx ic tc IIIC T80 C Dc Ta 40 C to 60 C cETL codes for Canada Ex nA ic IIC T5 Gc Ex n IIC T5 Gc Ex ic tc IIIC T80 C Dc Class III Div 2 Class II Div 2 Gp F G Ta 40 C to 60 C The ETL and...

Reviews: