6.20.8 Output pulse width:
durAtion
When
5CALEd
is selected in the
5ource
sub-function
(6.24.6) the output pulse width is defined by this
function. One of following millisecond pulse widths
may be selected:
0.. 1
0.. 5
1
2.. 5
5
10
25
50
100
250
500
Using the
&
or
*
push button select
durAtion
in
the pulse output sub-menu and press
(
which will
reveal the existing pulse duration. The value can be
changed by pressing the
&
or
*
push button to
select the required value followed by the
)
button to
return to
durAtion
prompt in the sub-menu.
Note:
This function only appears in the pulse output
sub-menu when
5CALEd
is selected in the
5ource
sub-function (6.20.6).
6.20.9 Pulse storage
If the
diVidE
and
durAtion
functions are configured
such that the output pulse frequency with the specified
pulse width can not be output in real time, the number
of pulses will be stored and transmitted at the
maximum possible speed.
When the total display is reset to zero or the power
supply to the Tachometer is disconnected or turned
off, any stored pulses will not be retained.