Technical data
Beijer Electronics AB, MA00557F
A-21
Technical data for CIMREX 90 and CIMREX 90D
Parameter
CIMREX 90
CIMREX 90D
Front panel, W x H x D 367 x 274 x 6 mm
Mounting depth
90 mm excl. D-sub, 110 mm incl. D-sub
Front panel seal
IP 65, NEMA 4
IP 65, NEMA 4X (indoor use only)
Rear panel seal
IP 20
Keyboard material/
front panel
Membrane switch keyboard with polyester domes.
Overlay film of Autotex F207 * with print on reverse side.
1 million operations.
Reverse side material Yellow-chromated steel plate.
Weight, excl. D-sub
3.5 kg
3.2 kg
Serial port RS422
25-pin D-sub contact, chassis-mounted female with standard lock-
ing screws 4-40 UNC.
Serial port RS232C
9-pin D-sub contact, chassis-mounted male with standard locking
screws 4-40 UNC.
Expansion slots
2
Flash memory for app-
lication
1,600 kb
Real time clock
±10 PPM + error because of ambient temperature and supply vol-
tage. Total max error 1 min/month = 12 min/year.
Minimum life of real time clock battery: 10 years
Power consumption at
rated voltage
Max: 0.17 – 0.35 A
(240 - 100 V AC)
1 A (24 V)
Display
TFT-LCD, 640 x 480 pixels, 256 colors, graphic and text. CCFL
backlight lifetime at the ambient temperature of +25
°
C: 50,000 h
Active area of dis-
play, W x H
211.2 x 158.4 mm
Color setting
The brightness of the colors is programmable.
Fuse
External AC: F2.5 A, Internal
DC: T4 A
External DC: F6.3 A,
Internal DC: T4 A
Power supply
100 - 240 V AC.
UL: Power Supply Cord - inten-
ded to be used with a listed/CN
cordset rated 250 V, minimum
10 A.
+24 V DC (20-30 V DC)
3-pin jack connection block.
CE: The power supply must
conform with the requirements
for SELV or PELV according to IEC
950 or IEC 742.
UL: The power supply must
conform with the requirements
for class II power supplies.
Ambient temperature 0
°
to +50
°
C
Summary of Contents for CIMREX 10
Page 1: ...CIMREX operator terminals Installation manual MA00557F 2004 04 Multi language...
Page 29: ...Beijer Electronics AB MA00557F 7 1 4 89 336 EEC EMC...
Page 94: ...Terminal drawings C 2 Beijer Electronics AB MA00557F CIMREX series Installation 24 V DC...
Page 95: ...Terminal drawings Beijer Electronics AB MA00557F C 3 CIMREX series Installation 115 230 V AC...
Page 97: ...Terminal drawings Beijer Electronics AB MA00557F C 5 232 25 ADP adapter to CIMREX 5...
Page 98: ...Terminal drawings C 6 Beijer Electronics AB MA00557F RS485 connection...
Page 100: ...Terminal drawings C 8 Beijer Electronics AB MA00557F CIMREX 5 Outline...
Page 101: ...Terminal drawings Beijer Electronics AB MA00557F C 9 CIMREX 10 Outline...
Page 102: ...Terminal drawings C 10 Beijer Electronics AB MA00557F CIMREX 12 Outline...
Page 103: ...Terminal drawings Beijer Electronics AB MA00557F C 11 CIMREX 20 Outline...
Page 104: ...Terminal drawings C 12 Beijer Electronics AB MA00557F CIMREX 30 Outline...
Page 105: ...Terminal drawings Beijer Electronics AB MA00557F C 13 CIMREX 41 Outline...
Page 106: ...Terminal drawings C 14 Beijer Electronics AB MA00557F CIMREX 60 Outline...
Page 107: ...Terminal drawings Beijer Electronics AB MA00557F C 15 CIMREX 67 CIMREX 69 CIMREX 69T Outline...
Page 108: ...Terminal drawings C 16 Beijer Electronics AB MA00557F CIMREX 70 Outline...
Page 109: ...Terminal drawings Beijer Electronics AB MA00557F C 17 CIMREX 90 Outline...
Page 110: ...Terminal drawings C 18 Beijer Electronics AB MA00557F CIMREX 90D Outline...
Page 111: ...Terminal drawings Beijer Electronics AB MA00557F C 19 CIMREX 91 Outline...
Page 112: ...Terminal drawings C 20 Beijer Electronics AB MA00557F CIMREX 91D Outline...