Parameter
Functional description
Setting range
Factory values
Customer
values
Arctis/
Duplex
Vulcano Cold
Rack/
Showca
ses
U2
K2 relay function.
See
U1
2
2
2
U3
K3 relay function.
See
U1
12
12
12
U4
K4 relay function.
See
U1
8
8
8
U5
K5 relay function.
See
U1
6
6
6
U6
K6 relay function.
See
U1
10
10
10
U7
K7 relay function.
See
U1
5
5
5
U8
K8 relay function.
See
U1
0
0
0
U9
Triac output function.
See
U1
0
0
0
U10
Triac output power limitation.
0 ... 100 %
80.0
80.0
80.0
U11
Upper limit for
U10
U12
… 100 %
100
100
100
U12
Lower limit for
U10
0 % …
U11
0.0
0.0
0.0
U99
Password for parameter level
U--
- 99 ... 999
- 19
- 19
- 19
Y--
Control loop 2 (password-protected)
Parameter
Functional description
Setting range
Factory values
Customer
values
Arctis/
Duplex
Vulcano Cold
Rack/
Showca
ses
Y0
Assignment of sensor for control
loop 2. Detailed description of the
sensors in parameters
H11
to
H53
0: None
1: Sensor F1
2: Sensor F2
3: Sensor F3
4: Sensor F4
5: Weighted average of F1 and F2
0
0
0
Y1
2nd control loop: Setpoint.
Y8
...
Y7
10.0
10.0
10.0
Y2
2nd control loop: Absolute or DeltaW
setpoint.
0: Absolute
1: DeltaW
0
0
0
Y4
2nd control loop: Switching direction. 0: Heating
1: Cooling
1
1
1
Y5
2nd control loop: Hysteresis.
0.1...99.0 °C
2.0
2.0
2.0
Y6
2nd control loop: Hysteresis mode.
0: Symmetrical
1: One-sided
1
1
1
Y7
Upper setpoint limit.
Y8
... + 999 °C
50.0
50.0
50.0
Y8
Lower setpoint limit.
- 99 °C ...
Y7
- 50
- 50
- 50
Y9
Function in case of sensor error.
0: Contact off
1: Contact on
1
1
1
Y10
Defrosting interval control loop 2.
0: No defrosting
1...99 h
0
0
0
Y11
Defrost time limit thermostat 2.
1...99 min
30
30
30
Y99
Password for parameter level
Y--
- 99 ... 999
- 19
- 19
- 19