Beer Grill AG
Beer Grill GmbH
Allmendstrasse 7
Tel. +41 56 618 7800
Körnerstrasse 14 a
Tel. +49 71 61 659 876
CH
– 5612 Villmergen,
Switzerland
Fax +41 56 618 7849
D
– 79539 Lörrach,
Germany
Fax +49 71 61 659 879
www.beergrill.com
Assembly-Programming-Instructions_Cold-Rack_e_05-10-2018
Page 36
Parameter
Functional description
Setting range
Factory values
Customer
values
Arctis/
Duplex
Vulcano Cold
Rack/
Showca
ses
H31
Sensor F3 actual value.
Measured value, not adjustable
H32
Sensor F3 calibration (actual value
correction).
- 20...+ 20.0 °C
0.0
0.0
0.0
H33
Sensor F3 weighting factor.
0.50...1.50
1.00
1.00
1.00
H34
Sensor F3 sensor selection.
See
H14
0
0
0
H35
Sensor F3 software filter.
1 .. 32
8
8
8
H36
Display at 0/4 mA and sensor selection
H34
= 7/8
- 99..+ 999
0.0
0.0
0.0
H37
Display at 20 mA and sensor selection
H34
= 7/8
- 99..+ 999
100
100
100
H41
Sensor F4 actual value.
Measured value, not adjustable
H42
Sensor F4 calibration (actual value
correction).
- 20...+ 20.0 °C
0.0
0.0
0.0
H43
Sensor F4 weighting factor.
0.50...1.50
1.00
1.00
1.00
H44
Sensor F4 sensor selection.
See
H14
0
0
0
H45
Sensor F4 software filter.
1 .. 32
8
8
8
H46
Display at 0/4 mA and sensor selection
H44
= 7/8
- 99..+ 999
0.0
0.0
0.0
H47
Display at 20 mA and sensor selection
H44
= 7/8
- 99..+ 999
100
100
100
H51
Display of weighted average of F1+F2
H51
= (
H53
*
H11
+ (100-
H53
) *
H21
)/100
H53
Weighting of sensor F1 for
H51
0 ... 100 %
100
100
100
H99
Password for parameter level
H--
- 99 ... 999
0
0
0
J--
Predefined parameter sets (password-protected)
Parameter
Functional description
Setting range
Factory values
Customer
values
Arctis/
Duplex
Vulcano Cold
Rack/
Showca
ses
J1
Parameter set.
0 ... 6
0
0
0
J98
Password
for
entering
the
level
selection (if
PA
is displayed).
- 99 ... 999
- 19
- 19
- 19
- 19
J99
Password for parameter level
J--
- 99 ... 999
- 19
- 19
- 19
- 19
Parameter
J98
is only visible and adjustable via the ST bus.
Attention:
Any change to the parameter set changes
all
parameter
settings!