Assembly-Programming-Instructions_Cold-Rack_e_05-10-2018
Page 37
L--
Networking and display (password-protected)
Parameter
Functional description
Setting range
Factory values
Customer
values
Arctis/
Duplex
Vulcano Cold
Rack/
Showca
ses
L0
Own ST bus address of the box
(corresponds to setting
Adr
).
0: Deactivated
1 ... 250
1
1
1
L2
Temperature scale.
0: Celsius
1: Fahrenheit
0
0
0
L3
Display mode for actual value.
0: Integer
1: Resolution 0.5 K
2: Resolution 0.1 K
2
2
2
L4
Measured value (display) parameter
address.
0...255
0
0
0
L6
Software version.
L7
Display during standby.
0: OFF
1: OFF
2: Right decimal point
3: Right decimal point flashing
0
0
0
L40
ST bus enable screen for functions.
0 .. 255
251
251
251
L41
ST bus enable screen for functions.
0 .. 255
255
255
255
L42
Enable for deleting counter/run times.
0: No enable
1: Delete is enabled for 10 min
(see A17, N98 and T98)
0
0
0
L99
Password for parameter level
L--
- 99 ... 999
- 19
- 19
- 19
U--
Relay contacts and lamps (password-protected)
Parameter
Functional description
Setting range
Factory values
Customer
values
Arctis/
Duplex
Vulcano Cold
Rack/
Showca
ses
U1
K1 relay function.
0: No function (off)
1: Compressor
2: Defrosting circuit 1
3: Evaporator fan
4: Condenser fan
5: Alarm
6: Control contact circuit 2
7: Defrosting circuit 2
8: Relay function A (light 1)
9: Relay function B (light 2)
10: Relay function C
11: Relay function D
12: Relay function E
13: Relay function F
14: Drip tray heating
15: Buzzer
16: On if controller active
17: On if control loop 1 is active
18: On if control loop 2 is active
19: On if Set 1 is active
20: On if Set 2 is active
21: On if day switching is active
22: On if night switching is active
23: On if Superfrost function active
24: Reheating during dehumidification
25: Humidification
1
1
1