Commissioning
CU8130-0240
19
Version: 1.1
6.1.2
Installing the mounting plate (optional)
In this chapter, we show you how to install a mounting plate on the UPS. With the mounting plate, the UPS
can subsequently be fastened to the rear panel of a control cabinet. To do this, the two DIN rail adapters and
the grounding springs on the rear side of the UPS have to be dismounted. The mounting plate is not included
in the scope of delivery (see:
).
Requirements:
• C9900-M675 mounting plate made of black anodized aluminum.
• Screwdrivers.
Install the mounting plate as follows:
1. Loosen the six M4 screws and remove the DIN rail adapter.
2. Loosen the M3 screws and remove the grounding springs from the UPS.
3. Fasten the mounting plate to the rear panel of the UPS with four M4 screws.