Decommissioning
96
───
Version: 1.0
eXtended Transport System
For more information please refer to Chapter: Documentation notes.
Disassembly may only be carried out by qualified and trained per-
sonnel.
When disposing of electronic waste, make sure that you dispose of
it in accordance with the regulations applicable in your country.
Read and follow the instructions for proper disposal.
13.1
Disassembly
WARNING
Risk of injury when disassembling the movers
Permanent magnets are installed in the magnetic plate sets of
the movers. Be careful when disassembling the magnetic plate
sets. Make sure that the magnetic plate sets do not magnetically
attract one another with your hands in-between.
If you don't take care during the disassembly, opposite magnetic
plate sets may attract each other without warning and injure your
hands.
Do not remove components from the products
Only Beckhoff Automation GmbH & Co. KG is permitted to remove
components.
Contact Beckhoff Service if you have any questions.
Removal of the XTS Hygienic from the machine
• Remove cables and electrical connections
• Loosen the fixing screws of the guide rails and the modules
• Remove the modules from the machine one after the other
• Transport the XTS Hygienic components to the workplace or put
them into storage