33
Displa
y
Console. The switches pictured on the page represent all possible options,
so your console may not have switches that are on the page. When you
operate each switch, the pictured switch on the page should move as you
move the switch on the Console. When diagnosing a problem, you can
test the switch and the computers response to the actuation. If the switch
moves on the screen as actuated, then the switch is operating properly as
well as the wiring of the input circuit, and the computer is receiving the
command. The problem then must be traced from the output node to the
function. The Station Shift switch directly controls the hydraulic valve
2
Propel
Press ❷ to enter and diagnose all aspects of the electronic side of the
propulsion system. Each square has a voltage reading corresponding to
each function. Below voltage the reading on the left is the status of the
circuit with the appropriate level being low, high, or OK. The right side
analyzes the feed back circuit with OK, or corrupt describing a bad signal or
no signal. The flashing red indicates a problem.
3
Gages
Press ❸ to enter and diagnose the gages and their sender outputs.
Each square has a voltage reading corresponding to each function.
Below voltage the reading on the left is the status of the circuit with the
appropriate level being low, high, or OK. The right side analyzes the feed
back circuit with OK, or corrupt describing a bad signal or no signal. The
flashing red indicates a problem.
4
Battery & Sensor
Pressing button ❹ will give power voltage readings for 4 of the major
computer controlled junction boxes. On the left is the input voltage for the
node. The decimal is missing so a reading of 146V is 14.6 volts. The right
side is the controlled and protected output voltage from each node to
sensors. The decimal is missing so a reading of 4976V is 4.976 volts.
5
Belts & Augers
Press ❺ to enter and diagnose the Belt and Auger sensors. Each square
has a voltage reading corresponding to each function. Below voltage
the reading on the left is the status of the circuit with the appropriate
level being low, high, or OK. The right side analyzes the feed back circuit
with OK, or corrupt describing a bad signal or no signal. The flashing red
indicates a problem. The Belt Valve and Auger Valve boxes light up when
the function is actuated.
6
Blank
Summary of Contents for BC-2016/CRC
Page 1: ...INSTRUCTION MANUAL 2016 Tandem Chip Spreader 8 16 10 20...
Page 8: ...8 2016...
Page 58: ...58 2016...
Page 59: ...59 www bearcatmfg com 928 684 7851 Parts Parts Manual...
Page 62: ...62 2016 Email Part Sales partsales bearcatmfg com A OPERATORS STATION 211737 Control Station...
Page 75: ...75 www bearcatmfg com 928 684 7851 Parts G3 211996 Valve Box G4 VLV 35008 Valve Bank...
Page 77: ...77 www bearcatmfg com 928 684 7851 Parts Page 2 of 2...
Page 83: ...83 www bearcatmfg com 928 684 7851 Parts H14 213177 Tier 4 Engine...
Page 85: ...85 www bearcatmfg com 928 684 7851 Parts H17 201662 Tier 3 Engine...
Page 86: ...86 2016 Hydraulics 210211 1 of 2 SCHEMATICS DRAWINGS...
Page 87: ...87 Maintenance Schematics Hydraulics 210211 2 of 2...
Page 88: ...88 2016 Junction Box 210313...
Page 89: ...89 Maintenance LH Valve Box 210180...
Page 90: ...90 2016 RH Valve Box 210181...
Page 91: ...91 Maintenance Operator Control Box 202541...
Page 92: ...92 2016 Slave Box 210149...
Page 93: ...93 Maintenance Pneumatics 200007...
Page 94: ...94 2016 Dash Panel 202540...