Installation manual
HB-37420-810-01-25F-EN SMX100 Installation manual.docx
Page 92 of 260
Version: 25F
Encoder A
Encoder B
Safe
speed
Safe
direction
Safe
absolute
position
Fault exclusion
DC
1-channel
partial system
2-channel
partial
system
dynamic
2-channel
partial
system
non-
dynamic
(standstill
monitoring)
SSI
Resolver
X
X
X
n.a.
99%
95-99%
SSI
SSI
X
X
X
n.a.
99%
90-95%
NC
SIN/COS
X
X
Fault exclusion mech. shaft breakage,
positive encoder shaft connection
required
90%
99%
90-95%
NC
Resolver
X
X
Fault exclusion mech. shaft breakage,
positive encoder shaft connection
required
90%
99%
90-95%
NC
HTL
X
Fault exclusion mech. shaft breakage,
positive encoder shaft connection
required
60%
99%
80-90%
2 x counter Proxi
90°
SSI
X
X
X
n.a.
99%
90-95%