Safety note:
•
The manufacturer's data (MTTF
D
, FIT-numbers, etc.) must be used for a safety related
assessment of the partial system "Sensors".
•
The DC-values listed in the table must be used conservatively and compliance with the
boundary conditions (see table under „Remarks“) must be ensured.
•
According to the applicable standards, fault exclusions are permitted. The boundary
conditions mentioned in this context must permanently be met.
•
If several sensor systems are required for the correct function of a single safety function,
their partial values must be correctly merged by following the chosen method. This applies
also for a combination of digital and analog sensors (e.g. safely reduced speed with open
safety door = door c encoder for speed detection)
4.2.3.1 Exemplary connection of analog sensors
By using suitable sensors and careful wiring of the sensor
OI e acc. to EN ISO 13849-1 can be achieved.
The analog current inputs are all equipped with the fixed loading resistor of 500Ohm. For analog
voltage inputs this resistor is omitted.
Safety note:
•
PI e acc. to EN ISO 134849-1 is achieved when using two non-reactive sensors, for which
Common Cause faults can be ruled out.